Durability of left bundle branch area pacing

Affiliations

Durability of left bundle branch area pacing

Nikhil A Mehta et al. J Cardiovasc Electrophysiol. 2022 Jul.

Abstract

Background: Left bundle branch area pacing (LBBAP) is a form of conduction system pacing. Long-term data on the safety and performance of LBBAP 1 year postdevice implantation has not been well described.

Methods and results: Sixty-five patients (49% females) who received LBBAP for bradycardia indications using the SelectSecure 3830 lead (Medtronic) were retrospectively evaluated. Clinical variables were examined. Lead parameters were obtained at implant and during regular follow-up. Mean age of patients was 75.7 ± 10.1 years with left ventricular ejection fraction 59.8 ± 10.4%. Indications for pacing were atrioventricular block 55%, sinus node dysfunction 19%, tachy-brady syndrome 15%, atrioventricular node ablation 8%, and bail out cardiac resynchronization therapy 3%. Mean baseline QRS measured 120 ± 38 ms, paced QRS duration was 138 ± 22ms. Paced QRS narrowed by 24 ms in those with pre-existing left bundle branch block (BBB), increased by 1 ms in those with pre-existing right BBB, and increased by 42 ms in those with no BBB. LBBAP threshold at implant was 0.521 ± 0.153 V at 0.4 ms, and increased to 0.654 ± 0.186 V at 3 months (+26%), 0.707 ± 0.186 V at 6 months (+36%), and 0.772 ± 0.220 V at 12 months (+48%). Patients with left BBB showed the maximum benefit with QRS narrowing 24 ms. Pacing impedance remained unchanged with no procedure-related complications.

Conclusion: LBBAP is a durable form of conduction system pacing with pacing thresholds remaining relatively stable over 12 months post device implantation. Patients with left BBB display the narrowest paced QRS.

Keywords: conduction system pacing; durability; left bundle branch pacing; physiologic pacing; threshold.

PubMed Disclaimer

Comment in

References

REFERENCES

    1. Ponnusamy SS, Arora V, Namboodiri N, Kumar V, Kapoor A, Vijayaraman P. Left bundle branch pacing: a comprehensive review. J Cardiovasc Electrophysiol. 2020;31(9):2462-2473.
    1. Vijayaraman P, Chung MK, Dandamudi G, et al. His bundle pacing. J Am Coll Cardiol. 2018;72(8):927-947.
    1. Bhatt AG, Musat DL, Milstein N, et al. The efficacy of his bundle pacing: lessons learned from implementation for the first time at an experienced electrophysiology center. JACC Clin Electrophysiol. 2018;4(11):1397-1406.
    1. Huang W, Su L, Wu S, et al. A novel pacing strategy with low and stable output: pacing the left bundle branch immediately beyond the conduction block. Can J Cardiol. 2017;33(12):1736 e1-e3.
    1. Hou X, Qian Z, Wang Y, et al. Feasibility and cardiac synchrony of permanent left bundle branch pacing through the interventricular septum. Europace. 2019;21(11):1694-702.

LinkOut - more resources