Randomized Controlled Trial
. 2022 Sep 1;235(3):401-409.
doi: 10.1097/XCS.0000000000000275. Epub 2022 Aug 10.

Biologic vs Synthetic Mesh for Parastomal Hernia Repair: Post Hoc Analysis of a Multicenter Randomized Controlled Trial

Affiliations
Randomized Controlled Trial

Biologic vs Synthetic Mesh for Parastomal Hernia Repair: Post Hoc Analysis of a Multicenter Randomized Controlled Trial

Benjamin T Miller et al. J Am Coll Surg. .

Abstract

Background: Parastomal hernias are often repaired with mesh to reduce recurrences, but the presence of an ostomy increases the wound class from clean to clean-contaminated/contaminated and makes the choice of mesh more controversial than in a strictly clean case. We aimed to compare the outcomes of biologic and synthetic mesh for parastomal hernia repair.

Study design: This is a post hoc analysis of parastomal hernia repairs in a randomized trial comparing biologic and synthetic mesh in contaminated ventral hernia repairs. Outcomes included rates of surgical site occurrences requiring procedural intervention (SSOPI), reoperations, stoma/mesh-related adverse events, parastomal hernia recurrence rates (clinical, patient-reported, and radiographic) at 2 years, quality of life (EQ-5D, EQ-5D Visual Analog Scale, and Hernia-Related Quality of Life Survey), and hospital costs up to 30 days.

Results: A total of 108 patients underwent parastomal hernia repair (57 biologic [53%] and 51 synthetic [47%]). Demographic and hernia characteristics were similar between the two groups. No significant differences in SSOPI rates or reoperations were observed between mesh types. Four mesh erosions into an ostomy requiring reoperations (2 biologic vs 2 synthetic) occurred. At 2 years, parastomal hernia recurrence rates were similar for biologic and synthetic mesh (17 [29.8%] vs 13 [25.5%], respectively; p = .77). Overall and hernia-related quality of life improved from baseline and were similar between the two groups at 2 years. Median total hospital cost and median mesh cost were higher for biologic compared with synthetic mesh.

Conclusion: Biologic and synthetic mesh have similar wound morbidity, reoperations, 2-year hernia recurrence rates, and quality of life in parastomal hernia repairs. Cost should be considered in mesh choice for parastomal hernia repairs.

Trial registration: ClinicalTrials.gov NCT02451176 NCT03972553.

PubMed Disclaimer

References

    1. Carne PW, Robertson GM, Frizelle FA. Parastomal hernia. Br J Surg 2003;90:784–793.
    1. Shah NR, Craft RO, Harold KL. Parastomal hernia repair. Surg Clin N Amer 2013;93:1185–1198.
    1. Murken DR, Bleier JIS. Ostomy-related complications. Clin Colon Rectal Surg 2019;32:176–182.
    1. van Dijk SM, Timmermans L, Deerenberg EB, et al. Parastomal hernia: Impact on quality of life? World J Surg 2015;39:2595–2601.
    1. Shellito PC. Complications of abdominal stoma surgery. Dis Colon Rectum 1998;41:1562–1572.