Pencil beam scanning proton FLASH maintains tumor control while normal tissue damage is reduced in a mouse model
- PMID: 35595175
- DOI: 10.1016/j.radonc.2022.05.014
Pencil beam scanning proton FLASH maintains tumor control while normal tissue damage is reduced in a mouse model
Abstract
Purpose: Preclinical studies indicate a normal tissue sparing effect when ultra-high dose rate (FLASH) radiation is used, while tumor response is maintained. This differential response has promising perspectives for improved clinical outcome. This study investigates tumor control and normal tissue toxicity of pencil beam scanning (PBS) proton FLASH in a mouse model.
Methods and materials: Tumor bearing hind limbs of non-anaesthetized CDF1 mice were irradiated in a single fraction with a PBS proton beam using either conventional (CONV) dose rate (0.33-0.63 Gy/s field dose rate, 244 MeV) or FLASH (71-89 Gy/s field dose rate, 250 MeV). 162 mice with a C3H mouse mammary carcinoma subcutaneously implanted in the foot were irradiated with physical doses of 40-60 Gy (8-14 mice per dose point). The endpoints were tumor control (TC) assessed as no recurrent tumor at 90 days after treatment, the level of acute moist desquamation (MD) to the skin of the foot within 25 days post irradiation, and radiation induced fibrosis (RIF) within 24 weeks post irradiation.
Results: TCD50 (dose for 50% tumor control) was similar for CONV and FLASH with values (and 95% confidence intervals) of 49.1 (47.0-51.4) Gy for CONV and 51.3 (48.6-54.2) Gy for FLASH. RIF analysis was restricted to mice with tumor control. Both endpoints showed distinct normal tissue sparing effect of proton FLASH with MDD50 (dose for 50% of mice displaying moist desquamation) of <40.1 Gy for CONV and 52.3 (50.0-54.6) Gy for FLASH, (dose modifying factor at least 1.3) and FD50 (dose for 50% of mice displaying fibrosis) of 48.6 (43.2-50.8) Gy for CONV and 55.6 (52.5-60.1) Gy for FLASH (dose modifying factor of 1.14).
Conclusions: FLASH had the same tumor control as CONV, but reduced normal tissue damage assessed as acute skin damage and radiation induced fibrosis.
Keywords: In vivo; Normal tissue damage; Proton FLASH; Tumor control.
Copyright © 2022 The Authors. Published by Elsevier B.V. All rights reserved.
Conflict of interest statement
Conflict of interest statement This study presented in this manuscript is partly funded by Varian. Two co-authors are co-inventors on a patent-application filled with application number 63257211 and EFS ID: 44064136, which contains parts of the data included in the manuscript.
Comment in
-
Commentary on the article: Sørensen BS et al., Pencil beam scanning proton FLASH maintains tumor control while normal tissue damage is reduced in a mouse model.Radiother Oncol. 2022 Oct;175:191-192. doi: 10.1016/j.radonc.2022.08.012. Epub 2022 Aug 18. Radiother Oncol. 2022. PMID: 35988775 No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources