. 2022 Oct;38(10):1907-1912.
doi: 10.1007/s00381-022-05552-1. Epub 2022 May 20.

Prediction of shunt failure facilitated by rapid and accurate volumetric analysis: a single institution's preliminary experience

Affiliations

Prediction of shunt failure facilitated by rapid and accurate volumetric analysis: a single institution's preliminary experience

Tushar R Jha et al. Childs Nerv Syst. 2022 Oct.

Abstract

Background: Shunt malfunction is a common complication and often presents with hydrocephalus. While the diagnosis is often supported by radiographic studies, subtle changes in CSF volume may not be detectable on routine evaluation. The purpose of this study was to develop a novel automated volumetric software for evaluation of shunt failure in pediatric patients, especially in patients who may not manifest a significant change in their ventricular size.

Methods: A single-institution retrospective review of shunted patients was conducted. Ventricular volume measurements were performed using manual and automated methods by three independent analysts. Manual measurements were produced using OsiriX software, whereas automated measurements were produced using the proprietary software. A p value < 0.05 was considered statistically significant.

Results: Twenty-two patients met the inclusion criteria (13 males, 9 females). Mean age of the cohort was 4.9 years (range 0.1-18 years). Average measured CSF volume was similar between the manual and automated methods (169.8 mL vs 172.5 mL, p = 0.56). However, the average time to generate results was significantly shorter with the automated algorithm compared to the manual method (2244 s vs 38.3 s, p < 0.01). In 3/5 symptomatic patients whose neuroimaging was interpreted as stable, the novel algorithm detected the otherwise radiographically undetectable CSF volume changes.

Conclusion: The automated software accurately measures the ventricular volumes in pediatric patients with hydrocephalus. The application of this technology is valuable in patients who present clinically without obvious radiographic changes. Future studies with larger cohorts are needed to validate our preliminary findings and further assess the utility of this technology.

Keywords: Hydrocephalus; Shunt failure; Volumetric analysis.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Bradley WG (2015) CSF Flow in the brain in the context of normal pressure hydrocephalus. Am J Neuroradiol 36:831–838. https://doi.org/10.3174/ajnr.A4124 - DOI - PubMed - PMC
    1. Wright Z, Larrew TW, Eskandari R (2016) Pediatric hydrocephalus: current state of diagnosis and treatment. Pediatr Rev 37:478–490. https://doi.org/10.1542/pir.2015-0134 - DOI - PubMed
    1. Flannery AM, Mitchell L (2014) Pediatric hydrocephalus: systematic literature review and evidence-based guidelines. Part 1: Introduction and methodology. J Neurosurg Pediatr 14(Suppl 1):3–7. https://doi.org/10.3171/2014.7.PEDS14321
    1. Simon TD, Riva-Cambrin J, Srivastava R et al (2008) Hospital care for children with hydrocephalus in the United States: utilization, charges, comorbidities, and deaths. J Neurosurg Pediatr 1:131–137. https://doi.org/10.3171/PED/2008/1/2/131 - DOI - PubMed
    1. Kestle JR (2003) Pediatric hydrocephalus: current management. Neurol Clin 21(883–895):vii. https://doi.org/10.1016/s0733-8619(03)00016-1 - DOI

LinkOut - more resources