. 2022;30(5):1147-1154.
doi: 10.3233/THC-213535.

Can tibia-first total knee arthroplasty using computer-assisted system improve anterior and posterior knee stability?

Affiliations

Can tibia-first total knee arthroplasty using computer-assisted system improve anterior and posterior knee stability?

Tsuneari Takahashi et al. Technol Health Care. 2022.

Abstract

Background: Total knee arthroplasty (TKA) is a widely performed procedure to alleviate pain and restore function of patients with end-stage knee osteoarthritis.

Objective: The study aim was to determine if tibia-first (TF) total knee arthroplasty (TKA) using a novel computer-assisted surgery (CAS) system can yield better anterior and posterior (AP) knee stability.

Methods: Patients with knee osteoarthritis with obvious varus knee who met the indication for and underwent TKA from May 2019 to November 2020 were included. Forty-one measured resection (MR)-TKAs and 32 TF-TKAs were compared. The varus-valgus ligament balance and joint tension at a joint center-gap setting equal to the tibial-baseplate thickness were measured, and appropriate polyethylene inserts with 0∘, 30∘, 45∘, 60∘, 90∘, and 120∘ of knee flexion were placed. A Kneelax 3 arthrometer was used to measure knee AP laxity in the postoperative anesthetized patients with 30∘ and 90∘ of knee flexion.

Results: The horizontal gap balance was significantly closer in the TF-TKA group than the MR-TKA group for 0∘, 30∘, 45∘, and 60∘ of knee flexion. In contrast, no significant differences were observed for 90∘ and 120∘ of knee flexion. No significant differences in joint-gap tensions among all knee-flexion angles were observed. Translation was significantly smaller in the TF-TKA group than the MR-TKA group for AP laxity with 30∘ of knee flexion (8.8 ± 2.9 mm vs. 10.7 ± 3.1 mm, P= 0.0079). In contrast, no significant AP laxity was observed with 90∘ of knee flexion (7.2 ± 2.8 mm vs. 7.2 ± 3.5 mm).

Conclusion: TF-TKA using a novel CAS system provided better AP knee stability with close to horizontal gap balances.

Keywords: Total knee arthroplasty; anterior and posterior knee stability; computer-assisted surgery; gap balance; tibia-first technique.