. 2022 May 13:78:103713.
doi: 10.1016/j.amsu.2022.103713. eCollection 2022 Jun.

Measuring serum sodium levels using blood gas analyzer and auto analyzer in heart and lung disease patients: A cross-sectional study

Affiliations

Measuring serum sodium levels using blood gas analyzer and auto analyzer in heart and lung disease patients: A cross-sectional study

Mahnaz Narimani Zamanabadi et al. Ann Med Surg (Lond). .

Abstract

Objective: Emergency services require precise and rapid measurement of electrolytes to initiate treatment. Blood gas analyzers (BGA) analyzes blood samples in seconds however, its accuracy is still debatable. The aim of this study was to compare the level of serum sodium measured through BGA and auto analyzer in the laboratory analyzers.

Methods: This cross-sectional study was performed on 79 patients with heart and lung disease in the intensive care unit of the center. Patient information was recorded along with serum sodium levels measured through BGA and auto analyzer in the laboratory.

Results: The mean sodium level measured by BGA was 138.38 mEq/L and by auto analyzer was 137.42 mEq/L. The difference was statistically significant, p = 0.007. Among lung disease patients, the mean sodium levels from BGA and autoanalyzer did not differ significantly p = 0.052 where in patients with heart disease, these levels were 138.54 mEq/L and 137.23 mEq/L, respectively. The difference was significantly different, p = 0.015. Acidic pH measured using BGA and autoanalyzer also differed significantly, p = 0.006.

Conclusion: Blood gas analyzer method has a high correlation with laboratory analyzer, but in cases of hypernatremia, the accuracy of blood gas analyzer method decreases and especially in acidosis and in patients with pulmonary problems, the difference with laboratory method increases.

Keywords: Blood gas analyzer; Laboratory analyzer; Sodium.

PubMed Disclaimer

Conflict of interest statement

The authors deny any conflict of interest in any terms or by any means during the study.

Figures

Fig. 1
Fig. 1
Frequency of age in the studied patients.

References

    1. Budak Y.U., Huysal K., Polat M. Use of a blood gas analyzer and a laboratory autoanalyzer in routine practice to measure electrolytes in intensive care unit patients. BMC Anesthesiol. 2012;12(1):17. - PMC - PubMed
    1. Vahabi S., Zaman M., Farzan B. Analysis of serum Calcium, Magnesium, and Parathyroid Hormone in neonates delivered following preeclampsia treatment. Cell. Mol. Biol. 2016;62(14):59–63. - PubMed
    1. Nadri S., Mahmoudvand H., Vahabi S. Effect of magnesium sulfate on morphine activity retention to control pain after herniorrhaphy. Pain Manag. 2017;7(2):119–125. - PubMed
    1. Cox C.J. Acute care testing: blood gases and electrolytes at the point of care. Clin. Lab. Med. 2001;21(2):321–336. - PubMed
    1. Cox C.J. Acute care testing. Blood gases and electrolytes at the point of care. Clin. Lab. Med. 2001;21(2):321–335. - PubMed