Abstract
Objective: This study was performed to investigate the efficacy and safety of robotic diagnostic coronary angiography.
Background: Robotic percutaneous coronary intervention is associated with marked reductions in physician radiation exposure. Development of robotic diagnostic coronary angiography might similarly impact occupational safety.
Methods: Stable patients referred for coronary angiography were prospectively enrolled. After obtaining vascular access, diagnostic catheters were manually advanced over a wire to the ascending aorta. All subsequent catheter movements were performed robotically. The primary endpoint was procedural success, defined as robotic completion of coronary angiography without conversion to a manual procedure and the absence of procedural major adverse cardiovascular events (MACE-cardiac death, cardiac arrest, or stroke) and major angiographic complications (coronary/aortic dissection or embolization). The primary hypothesis was that the observed rate of the primary endpoint, evaluated at the completion of coronary angiography, would meet a pre-specified performance goal of 74.5%.
Results: Among 46 consecutive patients (age 67 ± 12 years; 69.6% male), diagnostic coronary angiography was completed robotically in all cases without the need for manual conversion and without any MACE or major angiographic complications. Thus, procedural success was 100%, which was significantly higher than the pre-specified performance goal (p < 0.001). Robotic coronary angiography was completed using 2 [2, 3] catheters per case with a median procedural time of 15 [11, 20] minutes.
Conclusions: Robotic diagnostic coronary angiography was performed with 100% procedural success and no observed complications. These results support the performance of future studies to further explore robotic coronary angiography.
Keywords: cardiac catheterization; coronary angiography; robotic.
© 2022 Wiley Periodicals LLC.
Comment in
-
Robotic coronary angiography: Advantages of stepping back.Catheter Cardiovasc Interv. 2022 Aug;100(2):214-215. doi: 10.1002/ccd.30332. Catheter Cardiovasc Interv. 2022. PMID: 35920374 No abstract available.
References
REFERENCES
-
- Weisz G, Metzger C, Caputo RP, et al. Safety and feasibility of robotic percutaneous coronary intervention. J Am Coll Cardiol. 2013;61:1596-1600.
-
- Mahmud E, Naghi J, Ang L, et al. Demonstration of the safety and feasibility of robotically assisted percutaneous intervention in complex coronary lesions: results of the CORA-PCI study. J Am Coll Cardiol Intv. 2017;10:1320-1327.
-
- Elmaraezy A, Morra ME, Mohammed AT, et al. Risk of cataract among interventional cardiologists and catheterization lab staff: a systematic review and meta-analysis. Catheter Cardiovasc Interv. 2017;90:1-9.
-
- Andreassi MG, Piccaluga E, Gargani L, et al. Subclinical carotid atherosclerosis and early vascular aging from long-term low-dose ionizing radiation. J Am Coll Cardiol Intv. 2015;8:616-627.
-
- Roguin A, Goldstein J, Bar O. Brain and neck tumors among physicians performing interventional procedures. Am J Cardiol. 2012;111:1368-1372.
MeSH terms
LinkOut - more resources
Full Text Sources