Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Jun 1;23(6):399-405.
doi: 10.2459/JCM.0000000000001319.

Evaluation of robotic-assisted mitral surgery in a contemporary experience

Affiliations

Evaluation of robotic-assisted mitral surgery in a contemporary experience

Alfonso Agnino et al. J Cardiovasc Med (Hagerstown). .

Abstract

Aims: To evaluate the safety/effectiveness of a recently established robotic-assisted mitral surgery program.

Methods: Cohort study with prospective collection of clinical data of 59 consecutive recipients (May 2019-August 2021) of robotic-assisted (fourth-generation platform, DaVinci X) mitral valve repair for degenerative disease, using a totally endoscopic technique. Patients' selection was based on defined anatomical and clinical criteria. We established a dedicated multidisciplinary protocol to facilitate postoperative fast-tracking, and a systematic in-house clinical and echocardiographic follow-up at 3, 6, and 12 postoperative months.

Results: All patients (89.8% men, average age 58 ± 12 years) received mitral valve repair; there was no operative mortality, one conversion to sternotomy (1.7%) and one stroke (1.7%). Extubation within the operative theater occurred in 28.8%; average mechanical ventilation time and ICU stay was 2.8 ± 4.1 and 32.5 ± 15.8 h (after exclusion of one outlier, learning-curve period, suffering from perioperative stroke); average postoperative hospital stay was 6.8 ± 3.4 days and 96.6% of patients were discharged home. One patient was transfused (1.7%); there were no other complications. Follow-up revealed stability of the results of mitral repair, with one (1.7%) persistent (>2+/4+) mitral regurgitation, and stability of coaptation height over time. We observed optimal functional results (class I was 98% at 3 months and 96% at 12 months). Quarterly case load consistently increased during the experience.

Conclusion: This initial experience suggests the reliability and clinical safety of a recently established local robotic-assisted mitral surgery. This strategy can facilitate faster postoperative recovery, and its positioning in the therapeutic armamentarium needs to be defined.

PubMed Disclaimer

References

    1. Carpentier A, Loulmet D, Aupècle B, et al. Computer assisted open heart surgery: first case operated on with success. C R Acad Sci III 1998; 321:437–442.
    1. Mohr FW, Falk V, Diegeler A, et al. Computer-enhanced coronary artery bypass surgery. J Thorac Cardiovasc Surg 1999; 117:1212–1214.
    1. Cerny S. Robotic cardiac surgery in Europe – Status 2020. 34th EACTS Annual Meeting, Online virtual event. 8–10 October 2020.
    1. Mihaljevic T, Koprivanac M, Kelava M, et al. Value of robotically assisted surgery for mitral valve disease. JAMA Surg 2014; 149:679–686.
    1. Coyan G, Wei LM, Althouse A, et al. Robotic mitral valve operations by experienced surgeons are cost-neutral and durable at 1 year. J Thorac Cardiovasc Surg 2018; 156:1040–1047.