Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2021 Nov 28;7(3):100860.
doi: 10.1016/j.adro.2021.100860. eCollection 2022 May-Jun.

Successful Stereotactic Body Radiation Therapy for Postbrachytherapy Prostate Recurrence and Penile Bulb Metastasis

Affiliations
Case Reports

Successful Stereotactic Body Radiation Therapy for Postbrachytherapy Prostate Recurrence and Penile Bulb Metastasis

Deborah E Citrin et al. Adv Radiat Oncol. .
No abstract available

PubMed Disclaimer

Figures

Fig 1
Fig. 1
Suspicious lesion within the prostate. (A) Axial T2-weighted (T2W) magnetic resonance image (MRI). (B) b2000 diffusion-weighted (DW) MRI. (C) Coronal T2W MRI. (D) Dynamic contrast enhanced (DCE) MRI image shows a right midbase transition zone lesion suspicious for recurrent prostate cancer. The lesion shows focal intense 18F-DCFPyL uptake on axial (E) and coronal (F) fused positron emission tomography/computed tomography images (arrows).
Fig 2
Fig. 2
Suspicious lesion within the right penile bulb. (A) 18F-DCFPyL positron emission tomography (PET) and (B) fused PET/computed tomography images show focal intense uptake within the right penile bulb, which is confirmed by (C) axial T2W magnetic resonance imaging (MRI) (arrows). In (B), note the presence of brachytherapy seeds in proximity to the penile bulb lesion. The right penile bulb lesion (arrows) shows diffusion restriction at b2000 diffusion-weighted MRI (D) and focal early enhancement at dynamic contrast-enhanced MRI (E). (F) Additionally, this lesion shows distinct enhancement on computed tomography (arrow).
Fig 3
Fig. 3
Radiation treatment plan and imaging. (A) Axial and (B) sagittal images of a radiation treatment plan delivering 40 Gy in 5 fractions to the recurrent tumor within the prostate (gross tumor volume segmented orange and planning target volume segmented purple for the prostate tumor; gross tumor volume segmented orange and planning target volume segmented green for the penile bulb lesion). Dose colorwash is overlayed, showing a lower prescription dose to the penile bulb lesion. (C, D) Brachytherapy seed groups were contoured and used as fiducial markers.

Similar articles

References

    1. Ahmed KA, Davis BJ, Mynderse LA, et al. Comparison of biochemical failure rates between permanent prostate brachytherapy and radical retropubic prostatectomy as a function of posttherapy PSA nadir plus ‘X.’. Radiat Oncol. 2014;9:1. - PMC - PubMed
    1. Valle LF, Greer MD, Shih JH, et al. Multiparametric MRI for the detection of local recurrence of prostate cancer in the setting of biochemical recurrence after low dose rate brachytherapy. Diagn Interv Radiol. 2018;24:46–53. - PMC - PubMed
    1. Valle LF, Lehrer EJ, Markovic D, et al. A systematic review and meta-analysis of local salvage therapies after radiotherapy for prostate cancer. Eur Urol. 2021;80:280–292. - PMC - PubMed
    1. Fiaschetti V, Liberto V, Claroni G, et al. Relevance of computed tomography and magnetic resonance imaging for penile metastasis after prostatectomy: Uncommon case report and brief review of the literature. Radiol Case Rep. 2016;11:255–259. - PMC - PubMed
    1. De Luca F, Zacharakis E, Shabbir M, et al. Malignant priapism due to penile metastases: Case series and literature review. Arch Ital Urol Androl. 2016;88:150–152. - PubMed

Publication types

LinkOut - more resources