Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022;63(3):504-509.
doi: 10.1536/ihj.21-844.

Revival of the Forgotten

Affiliations
Free article

Revival of the Forgotten

Laura Rottner et al. Int Heart J. 2022.
Free article

Abstract

Pulmonary vein (PV) isolation (PVI) by continuous, transmural and durable lesions is decisive for ensuring long-term freedom from atrial fibrillation (AF). AF ablation requires irrigated tip catheters to reduce thromboembolic complications. This precluded temperature-controlled delivery of radiofrequency (RF) energy.The aim of this study was to evaluate feasibility, acute efficacy, and safety of an irrigated, temperature-controlled ablation catheter [DiamondTemp™ (DT) Medtronic®] for PVI.Consecutive patients with AF underwent PVI using the DT catheter combined with high-power short-duration RF applications. Ablation settings were (1) a catheter tip temperature limit of 60°C, (2) a temperature-controlled power of 50 W, and (3) application duration of 10 seconds. The primary endpoint was acute isolation of PVs, reassessed after a 30-minute waiting period. Secondary endpoints included procedural parameters (defined as a catheter tip temperature of 50°C > 3 seconds, an impedance drop of 5-10 Ω) and the occurrence of serious adverse events.Fifty consecutive patients [mean age 66 ± 12 years, 38 (76%) women, 24 patients with paroxysmal AF (48%)] were included. Median procedure and left atrial dwell time was 89 [68; 107] and 63 [52; 79] minutes, respectively. Mean number of RF applications was 59 ± 20, and mean total RF duration was 14 ± 6 minutes. Acute PVI was achieved in all patients solely using DT ablation. Acute PV reconnection within the waiting period occurred in five patients; all reconnected PVs were successfully reisolated. One major complication occurred.In this study, the DT ablation system demonstrated high acute efficacy for PVI. Temperature-controlled ablation in conjunction with high-power short-duration applications might be effectively supported.

Keywords: Atrial fibrillation; High-power short-duration; Temperature-controlled radiofrequency ablation.

PubMed Disclaimer