Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Oct;58(5):393-400.
doi: 10.1016/j.jcjo.2022.05.005. Epub 2022 Jun 1.

Clinical outcomes of a trifocal compared with an extended depth of focus IOL following bilateral cataract surgery

Affiliations

Clinical outcomes of a trifocal compared with an extended depth of focus IOL following bilateral cataract surgery

Marius A Scheepers et al. Can J Ophthalmol. 2023 Oct.

Abstract

Objective: To compare the visual and patient reported outcomes of 2 presbyopia-correcting intraocular lenses (IOLs).

Methods: A total of 134 eyes (67 patients) that underwent cataract surgery with either a trifocal IOL or an extended depth of focus (EDOF) IOL bilaterally and were assessed 3 months after surgery. Outcome measures were binocular distance-corrected visual acuity at near (40 cm), intermediate (60 cm), and distance (6 m); Akman modified Quality of Life (QOL) Questionnaire-14; and 10% contrast visual acuity at distance and near, with and without glare.

Results: Mean binocular logMAR visual acuity (VA) for the PanOptix compared with the Symfony lenses: distance-corrected near VA, 0.054 versus 0.228; distance-corrected intermediate VA, 0.019 versus 0.063; and distance-corrected distance VA, -0.016 versus -0.021. The QOL questionnaire showed that 62% of the PanOptix group and 48% of the Symfony group had little or no difficulty with all QOL-related tasks. In a multivariable model controlling for pupil size and angle kappa (chord mu distance, right eyes), the differences were -0.005 (range, -0.03-0.02) and 0.165 (range, 0.12-0.21), respectively. Also, 10% contrast acuity was comparable in the 2 different lenses and was unaffected by glare.

Conclusions: Binocular distance-corrected near VA was significantly better in the PanOptix group (p < 0.0001). This result remained statistically significant after controlling for pupil size and chord mu distance (p < 0.001). Intermediate and distance VAs were similar between the 2 groups. QOL scores were higher in the PanOptix group.

PubMed Disclaimer