Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 May 29;11(11):3062.
doi: 10.3390/jcm11113062.

The Use of Harmonic Focus and Thunderbeat Open Fine Jaw in Thyroid Surgery: Experience of a High-Volume Center

Affiliations

The Use of Harmonic Focus and Thunderbeat Open Fine Jaw in Thyroid Surgery: Experience of a High-Volume Center

Gian Luigi Canu et al. J Clin Med. .

Abstract

Background: In thyroid surgery, achieving accurate haemostasis is fundamental in order to avoid the occurrence of complications. Energy-based devices are currently extensively utilized in this field of surgery. This study aims to compare Harmonic Focus and Thunderbeat Open Fine Jaw with regard to surgical outcomes and complications. Methods: Patients submitted to total thyroidectomy in our center, between January 2017 and June 2020, were retrospectively analysed. Based on the energy-based device utilized, two groups were identified: Group A (Harmonic Focus) and Group B (Thunderbeat Open Fine Jaw). Results: A total of 527 patients were included: 409 in Group A and 118 in Group B. About surgical outcomes, the mean operative time was significantly shorter in Group B than in Group A (p < 0.001), while as regards complications, the occurrence of transient recurrent laryngeal nerve injury was significantly greater in Group B than in Group A (p = 0.019). Conclusions. Both Harmonic Focus and Thunderbeat Open Fine Jaw have proven to be effective devices. Operative times were significantly shorter in thyroidectomies performed with Thunderbeat Open Fine Jaw; however, the occurrence of transient recurrent laryngeal nerve injury was significantly greater in patients operated on with this device.

Keywords: Harmonic Focus; Thunderbeat Open Fine Jaw; complications; energy-based devices; thyroid surgery; thyroidectomy.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

References

    1. Materazzi G., Ambrosini C.E., Fregoli L., De Napoli L., Frustaci G., Matteucci V., Papini P., Bakkar S., Miccoli P. Prevention and management of bleeding in thyroid surgery. Gland Surg. 2017;6:510–515. doi: 10.21037/gs.2017.06.14. - DOI - PMC - PubMed
    1. Gambardella C., Polistena A., Sanguinetti A., Patrone R., Napolitano S., Esposito D., Testa D., Marotta V., Faggiano A., Calò P.G., et al. Unintentional recurrent laryngeal nerve injuries following thyroidectomy: Is it the surgeon who pays the bill? Int. J. Surg. 2017;41((Suppl. 1)):55–59. doi: 10.1016/j.ijsu.2017.01.112. - DOI - PubMed
    1. Calò P.G., Pisano G., Piga G., Medas F., Tatti A., Donati M., Nicolosi A. Postoperative hematomas after thyroid surgery. Incidence and risk factors in our experience. Ann. Ital. Chir. 2010;81:343–347. - PubMed
    1. Pisano G., Canu G.L., Erdas E., Medas F., Calò P.G. Tracheostomy after total thyroidectomy: Indications and results in a series of 3214 operations. Minerva Chir. 2019;74:277–278. doi: 10.23736/S0026-4733.19.07907-0. - DOI - PubMed
    1. Cocchiara G., Cajozzo M., Amato G., Mularo A., Agrusa A., Romano G. Terminal ligature of inferior thyroid artery branches during total thyroidectomy for multinodular goiter is associated with higher postoperative calcium and PTH levels. J. Visc. Surg. 2010;147:e329–e332. doi: 10.1016/j.jviscsurg.2010.08.020. - DOI - PubMed

LinkOut - more resources