. 2022 Aug;66(2):118-130.
doi: 10.1002/mus.27573. Epub 2022 Jun 13.

Single fiber electromyography and measuring jitter with concentric needle electrodes

Affiliations

Single fiber electromyography and measuring jitter with concentric needle electrodes

Donald B Sanders et al. Muscle Nerve. 2022 Aug.

Abstract

This monograph contains descriptions of the single fiber electromyography (SFEMG) method and of the more recently implemented method of recording jitter with concentric needle electrodes (CNEs). SFEMG records action potentials from single muscle fibers (SFAPs), which permits measuring fiber density (FD), a sensitive measure of reinnervation, and jitter, a sensitive measure of abnormal neuromuscular transmission (NMT). With voluntary activation, jitter is measured between two SFAPs with acceptable amplitude and rise time. With activation by axon stimulation, jitter is measured between the stimulus and individual SFAPs. Pitfalls due to unstable triggers and inconstant firing rates during voluntary activation and subliminal stimulation during axon stimulation should be identified and avoided. In CNE recordings, spikes with shoulders or rising phases that are not parallel are produced by summation of SFAPS; these should be excluded and reference values for CNE jitter should be used. CNE and SFEMG have similar and very high sensitivity in detecting increased jitter, as in myasthenia gravis and other myasthenic conditions. However, jitter is also seen in ongoing reinnervation and some myopathic conditions. With SFEMG, these can be identified by increased FD; however, FD cannot be measured with CNE, and conventional electromyography should be performed in muscles with increased jitter to detect neurogenic or myogenic abnormalities. Jitter is abnormal after injections of botulinum toxin, even in muscles remote from the injection site, and can persist for 6 mo or more. This can complicate the detection or exclusion of abnormal NMT.

Keywords: concentric needle electrodes; jitter; myasthenia gravis; neuromuscular transmission; single fiber EMG.

PubMed Disclaimer

References

REFERENCES

    1. Stålberg EV, Trontelj JV, Sanders DB. Single fiber EMG. Edshagen Publishing House; 2010.
    1. Gilchrist JM. Ad hoc committee of the AAEM special interest group on single fiber EMG. Single fiber EMG reference values: a collaborative effort. Muscle Nerve. 1992;15:151-161.
    1. Stålberg E. Propagation velocity in human single muscle fibres in situ. Thesis Acta Physiol Scand. 1966;70(Suppl 287):1-112.
    1. Pitt MC. Use of stimulated electromyography in the analysis of the neuromuscular junction in children. Muscle Nerve. 2017;56(5):841-847.
    1. Stålberg E, Trontelj JV. Abnormal discharges generated within the motor unit as observed with single fibre electromyography. In: Ochoa JL, Culp B, eds. Abnormal Nerves and Muscles as Impulse Generators. Oxford University Press; 1982:443-474.

Publication types

LinkOut - more resources