Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Aug;33(8):1647-1654.
doi: 10.1111/jce.15595. Epub 2022 Jun 21.

Automated detection of atrial fibrillation based on vocal features analysis

Affiliations

Automated detection of atrial fibrillation based on vocal features analysis

Gregory Golovchiner et al. J Cardiovasc Electrophysiol. 2022 Aug.

Abstract

Introduction: Early detection of atrial fibrillation (AF) is desirable but challenging due to the often-asymptomatic nature of AF. Known screening methods are limited and most of them depend of electrocardiography or other techniques with direct contact with the skin. Analysis of voice signals from natural speech has been reported for several applications in medicine. The study goal was to evaluate the usefulness of vocal features analysis for the detection of AF.

Methods: This prospective study was performed in two medical centers. Patients with persistent AF admitted for cardioversion were enrolled. The patients pronounced the vowels "Ahh" and "Ohh" were recorded synchronously with an ECG tracing. An algorithm was developed to provide an "AF indicator" for detection of AF from the speech signal.

Results: A total of 158 patients were recruited. The final analysis of "Ahh" and "Ohh" syllables was performed on 143 and 142 patients, respectively. The mean age was 71.4 ± 9.3 and 43% of patients were females. The developed AF indicator was reliable. Its numerical value decreased significantly in sinus rhythm (SR) after the cardioversion ("Ahh": from 13.98 ± 3.10 to 7.49 ± 1.58; "Ohh": from 11.39 ± 2.99 to 2.99 ± 1.61). The values at SR were significantly more homogenous compared to AF as indicated by a lower standard deviation. The area under the receiver operating characteristic curve was >0.98 and >0.89 ("Ahh" and "Ohh," respectively, p < .001). The AF indicator sensitivity is 95% with 82% specificity.

Conclusion: This study is the first report to demonstrate feasibility and reliability of the identification of AF episodes using voice analysis with acceptable accuracy, within the identified limitations of our study methods. The developed AF indicator has higher accuracy using the "Ahh" syllable versus "Ohh."

Keywords: atrial fibrillation diagnosis; atrial fibrillation screening; vocal features; voice analysis.

PubMed Disclaimer

References

REFERENCES

    1. Hindricks G, Potpara T, Dagres N, et al. ESC Scientific Document Group. European 2020 ESC guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European association for cardio-thoracic surgery (EACTS) the task force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology (ESC) developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC authors/task force members. Eur Heart J. 2021;42(5):373-498.
    1. Chugh SS, Havmoeller R, Narayanan K, et al. Worldwide epidemiology of atrial fibrillation: a global burden of disease 2010. Circulation. 2014;129:837-847.
    1. Rahman F, Kwan GF, Benjamin EJ. Global epidemiology of atrial fibrillation. Nat Rev Cardiol. 2014;11:639-654.
    1. Schnabel RB, Yin X, Gona P, et al. 50 year trends in atrial fibrillation prevalence, incidence, risk factors, and mortality in the Framingham Heart Study: a cohort study. Lancet. 2015;386:154-162.
    1. Krijthe BP, Kunst A, Benjamin EJ, et al. Projections on the number of individuals with atrial fibrillation in the European Union, from 2000 to 2060. Eur Heart J. 2013;34:2746-2751.

Publication types

Grants and funding