Clinical Trial
. 2022 Dec;96(6):1021-1032.e2.
doi: 10.1016/j.gie.2022.06.019. Epub 2022 Jun 18.

Implementation of optical diagnosis with a "resect and discard" strategy in clinical practice: DISCARD3 study

Affiliations
Clinical Trial

Implementation of optical diagnosis with a "resect and discard" strategy in clinical practice: DISCARD3 study

Ahmir Ahmad et al. Gastrointest Endosc. 2022 Dec.

Abstract

Background and aims: Optical diagnosis (OD) of polyps can be performed with advanced endoscopic imaging. For high-confidence diagnoses, a "resect and discard" strategy could offer significant histopathology time and cost savings. The implementation threshold is a ≥90% OD-histology surveillance interval concordance. Here we assessed the OD learning curve and feasibility of a resect and discard strategy for ≤5-mm and <10-mm polyps in a bowel cancer screening setting.

Methods: In this prospective feasibility study, 8 bowel cancer screening endoscopists completed a validated OD training module and performed procedures. All <10-mm consecutive polyps had white-light and narrow-band images taken and were given high- or low-confidence diagnoses until 120 high-confidence ≤5-mm polyp diagnoses had been performed. All polyps had standard histology. High-confidence OD errors underwent root-cause analysis. Histology and OD-derived surveillance intervals were calculated.

Results: Of 565 invited patients, 525 patients were included. A total of 1560 <10-mm polyps underwent OD and were resected and retrieved (1329 ≤5 mm and 231 6-9 mm). There were no <10-mm polyp cancers. High-confidence OD was accurate in 81.5% of ≤5-mm and 92.8% of 6-9-mm polyps. Sensitivity for OD of a ≤5-mm adenoma was 93.0% with a positive predictive value of 90.8%. OD-histology surveillance interval concordance for ≤5-mm OD was 91.3% (209/229) for U.S. Multi-Society Task Force, 98.3% (225/229) for European Society of Gastrointestinal Endoscopy, and 98.7% (226/229) for British Society of Gastroenterology guidelines, respectively.

Conclusions: A resect and discard strategy for high-confidence ≤5-mm polyp OD in a group of bowel cancer screening colonoscopists is feasible and safe, with performance exceeding the 90% surveillance interval concordance required for implementation in clinical practice. (Clinical trial registration number: NCT04710693.).

PubMed Disclaimer

Comment in

Publication types

Associated data