. 2022 Jun 9;8(3):1509-1521.
doi: 10.3390/tomography8030124.

Dynamic Contrast Enhanced Study in Multiparametric Examination of the Prostate-Can We Make Better Use of It?

Affiliations

Dynamic Contrast Enhanced Study in Multiparametric Examination of the Prostate-Can We Make Better Use of It?

Silva Guljaš et al. Tomography. .

Abstract

We sought to investigate whether quantitative parameters from a dynamic contrast-enhanced study can be used to differentiate cancer from normal tissue and to determine a cut-off value of specific parameters that can predict malignancy more accurately, compared to the obturator internus muscle as a reference tissue. This retrospective study included 56 patients with biopsy proven prostate cancer (PCa) after multiparametric magnetic resonance imaging (mpMRI), with a total of 70 lesions; 39 were located in the peripheral zone, and 31 in the transition zone. The quantitative parameters for all patients were calculated in the detected lesion, morphologically normal prostate tissue and the obturator internus muscle. Increase in the Ktrans value was determined in lesion-to-muscle ratio by 3.974368, which is a cut-off value to differentiate between prostate cancer and normal prostate tissue, with specificity of 72.86% and sensitivity of 91.43%. We introduced a model to detect prostate cancer that combines Ktrans lesion-to-muscle ratio value and iAUC lesion-to-muscle ratio value, which is of higher accuracy compared to individual variables. Based on this model, we identified the optimal cut-off value with 100% sensitivity and 64.28% specificity. The use of quantitative DCE pharmacokinetic parameters compared to the obturator internus muscle as reference tissue leads to higher diagnostic accuracy for prostate cancer detection.

Keywords: magnetic resonance imaging; muscle; perfusion; permeability; prostate cancer.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Similar articles

Cited by

References

    1. Berman R., Brown A.M., Chang S.D., Sankineni S., Kadakia M., Wood B., Pinto P.A., Choyke P.L., Turkbey B. DCE MRI of prostate cancer. Abdom. Radiol. 2016;41:844–853. doi: 10.1007/s00261-015-0589-3. - DOI - PMC - PubMed
    1. Guo R., Cai L., Fan Y., Jin J., Zhou L., Zhang K. Magnetic resonance imaging on disease reclassification among active surveillance candidates with low-risk prostate cancer: A diagnostic meta-analysis. Prostate Cancer Prostatic Dis. 2015;18:221–228. doi: 10.1038/pcan.2015.20. - DOI - PubMed
    1. Rosenkrantz A., editor. MRI of the Prostate: A Practical Approach. Thieme; New York, NY, USA: Stuttgart, Germany: Delhi, India: Rio de Janeiro, Brazil: 2016.
    1. Ghai S., Haider M.A. Multiparametric-MRI in diagnosis of prostate cancer. Indian J. Urol. 2015;31:194–201. doi: 10.4103/0970-1591.159606. - DOI - PMC - PubMed
    1. Hoeks C.M.A., Hambrock T., Yakar D., De Kaa C.A.H., Feuth T., Witjes J.A., Fütterer J.J., Barentsz J.O. Transition Zone Prostate Cancer: Detection and Localization with 3-T Multiparametric MR Imaging. Radiology. 2013;266:207–217. doi: 10.1148/radiol.12120281. - DOI - PubMed

MeSH terms