Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Jul 20;60(7):e0042122.
doi: 10.1128/jcm.00421-22. Epub 2022 Jun 27.

Accuracy of Tongue Swab Testing Using Xpert MTB-RIF Ultra for Tuberculosis Diagnosis

Affiliations

Accuracy of Tongue Swab Testing Using Xpert MTB-RIF Ultra for Tuberculosis Diagnosis

A Andama et al. J Clin Microbiol. .

Abstract

Tongue dorsum swabs have shown promise as alternatives to sputum for detecting Mycobacterium tuberculosis (MTB) in patients with pulmonary tuberculosis (TB). Some of the most encouraging results have come from studies that used manual quantitative PCR (qPCR) to analyze swabs. Studies using the automated Cepheid Xpert MTB/RIF Ultra qPCR test (Xpert Ultra) have exhibited less sensitivity with tongue swabs, possibly because Xpert Ultra is optimized for testing sputum, not tongue swab samples. Using two new sample preprocessing methods that demonstrated good sensitivity in preliminary experiments, we assessed diagnostic accuracy and semi-quantitative signals of Xpert Ultra performed on tongue swabs collected from 183 adults with presumed TB in Kampala, Uganda. Relative to a sputum Xpert Ultra reference standard, the sensitivity of tongue swab Xpert Ultra was 77.8% (95% confidence interval [CI] 64.4-88.0) and specificity was 100.0% (95% CI, 97.2-100.0). When compared to a microbiological reference standard (MRS) incorporating both sputum Xpert Ultra and sputum mycobacterial culture, sensitivity was 72.4% (95% CI, 59.1-83.3) and specificity remained the same. Semi-quantitative Xpert Ultra results were generally lower with tongue swabs than with sputum, and cycle threshold values were higher. None of the eight sputum Xpert Ultra "trace" or "very low" results were detected using tongue swabs. Tongue swabs should be considered when sputum cannot be collected for Xpert Ultra testing, or in certain mass-screening settings. Further optimization of tongue swab analysis is needed to achieve parity with sputum-based molecular testing for TB.

Keywords: diagnostics; oral swab analysis; tongue swab; tuberculosis.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

References

    1. World Health Organization. 2020. Global Tuberculosis Report 2020. World Health Organization, Geneva, Switzerland.
    1. Cohen JF, Korevaar DA, Altman DG, Bruns DE, Gatsonis CA, Hooft L, Irwig L, Levine D, Reitsma JB, de Vet HCW, Bossuyt PMM. 2016. STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration. BMJ Open 6:e012799. doi: 10.1136/bmjopen-2016-012799. - DOI - PMC - PubMed
    1. World Health Organization. 2015. The use of lateral flow urine lipoarabinomannan assay (LF-LAM) for the diagnosis and screening of active tuberculosis in people living with HIV: Policy guidance. https://apps.who.int/iris/handle/10665/193633.
    1. Denkinger CM, Kik SV, Cirillo DM, Casenghi M, Shinnick T, Weyer K, Gilpin C, Boehme CC, Schito M, Kimerling M, Pai M. 2015. Defining the needs for next generation Assays for Tuberculosis. J Infectious Diseases 211:S29–S38. doi: 10.1093/infdis/jiu821. - DOI - PMC - PubMed
    1. Valinetz ED, Cangelosi GA. 2021. A look inside: oral sampling for detection of non-oral infectious diseases. J Clin Microbiol 59 JCM.02360-20. doi: 10.1128/JCM.02360-20. - DOI - PMC - PubMed

Publication types