Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Nov;38(11):2960-2968.
doi: 10.1016/j.arthro.2022.06.018. Epub 2022 Jun 28.

Anterolateral Acromioplasty Does Not Change the Critical Shoulder Angle and Acromion Index in a Clinically Relevant Amount

Affiliations

Anterolateral Acromioplasty Does Not Change the Critical Shoulder Angle and Acromion Index in a Clinically Relevant Amount

Sophie Thiesemann et al. Arthroscopy. 2022 Nov.

Abstract

Purpose: Assessment on whether radiographic parameters of the acromion measured in radiographs change significantly after anterolateral acromioplasty.

Methods: This retrospective study included patients that underwent an arthroscopic anterolateral acromioplasty between January 2014 and September 2020. n = 435 subjects with high-quality preoperative and postoperative radiographs according to Suter-Henninger criteria were included in the final assessment. All measurements were independently performed by the first and second author in a blinded fashion using dicomPACS software: acromion index (AI), critical shoulder angle (CSA), lateral acromial angle (LAA), beta angle, acromio-humeral distance (AHD), Aoki angle, frontal supraspinatus outlet angle (FSOW), and acromion type, according to Bigliani. SPSS software was used for statistical analysis.

Results: The beta angle and the CSA did not significantly change after operation (alpha power 0.32 and 0.11, respectively). In a subgroup analysis of patients with a pathological CSA >35° (n = 194), the CSA changed from 38.62 (range: 35.08-47.52, SD 2.83) to 38.04 (range: 29.18-48.12, SD 3.77) postoperatively (P = .028) (Fig 8). All other parameters changed significantly after operation (AI, AHD, FSOW, and Aoki; P = .001, LAA; P = .039) (Fig. 9). The interobserver and intraobserver reliability was good to excellent in the majority of measured values. Mean patient age was 59.2 years (range: 18.1-87.1; SD 11.3), mean height was 1.73 meters (range: 1,50-1.98, SD 0.09), mean weight was 80.2 kg (range: 37.0-133.0, SD 16.68), and mean body mass index was 26.6 (range: 0.0-46.1, SD 4.73).

Conclusion: Anterolateral acromioplasty producing a flat acromion undersurface did not result in a significant change of the CSA in the study population. Pathological preoperative CSA values of >35° were significantly reduced but not to normal values, but only by a small amount that puts the clinical relevance into question.

Level of evidence: IV, diagnostic study, case series.

PubMed Disclaimer

Comment in