Observational Study
. 2022 Dec;22(12):2961-2970.
doi: 10.1111/ajt.17137. Epub 2022 Jul 14.

Airway replacement using stented aortic matrices: Long-term follow-up and results of the TRITON-01 study in 35 adult patients

Affiliations
Free article
Observational Study

Airway replacement using stented aortic matrices: Long-term follow-up and results of the TRITON-01 study in 35 adult patients

Emmanuel Martinod et al. Am J Transplant. 2022 Dec.
Free article

Abstract

Over the past 25 years, we have demonstrated the feasibility of airway bioengineering using stented aortic matrices experimentally then in a first-in-human trial (n = 13). The present TRITON-01 study analyzed all the patients who had airway replacement at our center to confirm that this innovative approach can be now used as usual care. For each patient, the following data were prospectively collected: postoperative mortality and morbidity, late airway complications, stent removal and status at last follow-up on November 2, 2021. From October 2009 to October 2021, 35 patients had airway replacement for malignant (n = 29) or benign (n = 6) lesions. The 30-day postoperative mortality and morbidity rates were 2.9% (n = 1/35) and 22.9% (n = 8/35) respectively. At a median follow-up of 29.5 months (range 1-133 months), 27 patients were alive. There have been no deaths directly related to the implanted bioprosthesis. Eighteen patients (52.9%) had stent-related granulomas requiring a bronchoscopic treatment. Ten among 35 patients (28.6%) achieved a stent free survival. The actuarial 2- and 5-year survival rates (Kaplan-Meier estimates) were respectively 88% and 75%. The TRITON-01 study confirmed that airway replacement using stented aortic matrices can be proposed as usual care at our center. Clinicaltrials.gov Identifier: NCT04263129.

Keywords: airway replacement/pulmonology; clinical research/practice; surgical technique; tissue/organ engineering; translational research/science.

PubMed Disclaimer

Comment in

  • Tracheal replacement: A never-ending search.
    Rendina EA, Patterson GA. Rendina EA, et al. Am J Transplant. 2022 Dec;22(12):2721-2722. doi: 10.1111/ajt.17179. Epub 2022 Sep 6. Am J Transplant. 2022. PMID: 35986710 No abstract available.

References

REFERENCES

    1. Rusch VW. Has reconstruction of the central airways been transformed? From Aorta to Trachea. JAMA. 2018;319:2177-2178.
    1. Udelsman B, Mathisen DJ, Ott HC. A reassessment of tracheal substitutes - a systematic review. Ann Cardiothorac Surg. 2018;7:175-182.
    1. Greaney AM, Niklason LE. The history of engineered tracheal replacements: interpreting the past and guiding the future. Tissue Eng Part B Rev. 2021;27:341-352.
    1. Randhawa SK, Patterson GA. Single-stage tracheal transplantation - from bench to bedside. Am J Transplant. 2021;21:3223-3224.
    1. Damiano G, Palumbo VD, Fazzotta S, et al. Current strategies for tracheal replacement: a review. Life. 2021;11:618.

Publication types

Associated data

LinkOut - more resources