An unusual foreign body in the oral cavity: a case report from a patient safety point of view and literature review

Affiliations
Review

An unusual foreign body in the oral cavity: a case report from a patient safety point of view and literature review

Mariko Ito et al. J Anesth. 2022 Aug.

Abstract

Accidental foreign bodies (FBs) in the oral cavity, airway, esophagus and breathing circuit associated with anesthetic procedures are rare but can cause serious and life-threatening complications. We here present a case in which an unusual FB in the oral cavity was found after emergence from general anesthesia. The FB was later identified as a melted cap of a felt-tip pen. We investigated the cleaning process for reusable materials and concluded that the FB was accidentally placed in the inner lumen of the reusable bite block during the cleaning process. We then performed a review of the literature on FBs other than those of dental origin which were entrapped in the oral cavity, pharynx, larynx, trachea, esophagus, and anesthetic breathing circuit due to anesthetic procedures. From our case and 53 cases found in the search, we concluded that 1) use of disposable medical devices is recommended, 2) FBs can easily migrate into the oral cavity and airway during anesthesia, 3) delayed FB recognition may be associated with difficult intubation situations, and 4) more attention should be paid to the possibility of any medical or non-medical device becoming an FB during anesthesia.

Keywords: Airway; Foreign body; Oral cavity; Patient safety; Reusable medical device.

PubMed Disclaimer

References

    1. Foreman MJ, Moyes DG. Anaesthetic breathing circuit obstruction due to blockage of tracheal tube connector by a foreign body-two cases. Anaesth Intensive Care. 1999;27:73–5. - PubMed - DOI
    1. Athanassoglou V, Patel A, McGuire B, Higgs A, Dover MS, Brennan PA, Banerjee A, Bingham B, Pandit JJ. Systematic review of benefits or harms of routine anaesthetist-inserted throat packs in adults: practice recommendations for inserting and counting throat packs: An evidence-based consensus statement by the Difficult Airway Society (DAS), the British Association of Oral and Maxillofacial Surgery (BAOMS) and the British Association of Otorhinolaryngology, Head and Neck Surgery (ENT-UK). Anaesthesia. 2018;73:612–8. - PubMed - DOI
    1. Schaffraniets L, Graz F, Tamke A. Intratracheal foreign body caused by a sheared endotracheal intubation stylet. Anaesthesist. 2019;58:1223–5. - DOI
    1. Karamustafaoglu YA, Yanik F, Yoruk Y. A rare cause of cough: An unnoticed broken metallic stylet in trachea. Indian J Thorac Cardiovasc Surg. 2012;28:270–1. - DOI
    1. Chalhoub V, Richa F, El-Rassi I, Dagher C, Yazbeck P. Pulmonary migration of a fragment of plastic coating sheared from a stylet. J Emerg Med. 2013;44:1097–100. - PubMed - DOI

LinkOut - more resources