Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Jul 6;14(1):91.
doi: 10.1186/s13098-022-00865-2.

Oral glucose tolerance testing at 1 h and 2 h: relationship with glucose and cardiometabolic parameters and agreement for pre-diabetes diagnosis in patients with morbid obesity

Affiliations

Oral glucose tolerance testing at 1 h and 2 h: relationship with glucose and cardiometabolic parameters and agreement for pre-diabetes diagnosis in patients with morbid obesity

Vanessa Guerreiro et al. Diabetol Metab Syndr. .

Abstract

Background: One hour plasma glucose concentration (1hPG) during an oral glucose tolerance test (OGTT) may be an alternative to 2-h plasma glucose concentration (2hPG) in the identification of individuals at increased risk of hyperglycaemia, although its role is not fully understood.

Aim: We aim to investigate the relationship of these measures with other glucose parameters, as well as their relationship with cardiometabolic risk markers and the level of agreement for prediabetes mellitus diagnosis, in a sample of patients with morbid obesity.

Methods: We retrospectively evaluated 656 patients with morbid obesity without diagnosed diabetes. To define prediabetes with 2hPG, 2022 American Diabetes Association guidelines criteria were used, while for 1hPG, glucose ≥ 155 mg/dL was considered. Cohen's Kappa coefficient was used to assess the agreement between both measures of prediabetes mellitus diagnosis.

Results: A Cohen's Kappa coefficient of 0.405 (p < 0.001) was obtained. The 1hPG were positively correlated with homeostatic model assessment for insulin resistance (HOMA-IR) (ρ = 0.281, p < 0.001), fasting plasma glucose (FPG) (ρ = 0.581, p < 0.001), glycated haemoglobin (Hb1AC) (ρ = 0.347, p < 0.001) and were negatively correlated with homeostatic model assessment for cell-β function (HOMA-β) (ρ = -0.092, p = 0.018). 2hPG were also correlated with the same parameters, except for HOMA-β.

Conclusion: A fair agreement between 1 and 2hPG was verified. 1hPG criteria may be a useful indicator of β-cell dysfunction and insulin resistance in patients with morbid obesity without diabetes diagnosis.

Keywords: Obesity; Oral glucose tolerance testing; Prediabetes mellitus.

PubMed Disclaimer

Conflict of interest statement

The authors declare that they have no conflict of interest.

References

    1. James WP. Obesity—a modern pandemic: the burden of disease. Endocrinol Nutr. 2013;60(Suppl 1):3–6. - PubMed
    1. Pi-Sunyer X. The medical risks of obesity. Postgrad Med. 2009;121(6):21–33. doi: 10.3810/pgm.2009.11.2074. - DOI - PMC - PubMed
    1. Obesity: preventing and managing the global epidemic. Report of a WHO consultation. World Health Organ Tech Rep Ser. 2000;894:i-xii, 1–253. - PubMed
    1. Nathan DM, Davidson MB, DeFronzo RA, Heine RJ, Henry RR, Pratley R, et al. Impaired fasting glucose and impaired glucose tolerance: implications for care. Diabetes Care. 2007;30(3):753–759. doi: 10.2337/dc07-9920. - DOI - PubMed
    1. Coutinho M, Gerstein HC, Wang Y, Yusuf S. The relationship between glucose and incident cardiovascular events. A metaregression analysis of published data from 20 studies of 95,783 individuals followed for 12.4 years. Diabetes Care. 1999;22(2):233–240. doi: 10.2337/diacare.22.2.233. - DOI - PubMed

LinkOut - more resources