Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 1987 Jun;105(6):770-3.
doi: 10.1001/archopht.1987.01060060056032.

Aqueous misdirection and flat chamber after posterior chamber implants with and without trabeculectomy

Case Reports

Aqueous misdirection and flat chamber after posterior chamber implants with and without trabeculectomy

K F Tomey et al. Arch Ophthalmol. 1987 Jun.

Abstract

Three patients developed flat anterior chamber and were ultimately diagnosed as having aqueous misdirection after trabeculectomy with extracapsular cataract extraction and posterior chamber lens implantation (glaucoma triple procedure). A fourth patient developed aqueous misdirection after posterior chamber lens implantation only (without trabeculectomy). This latter was cured by repeated pars plana vitrectomy, not requiring removal of the pseudophakos. In only one of the three eyes with the triple procedure did the lens have to be removed and anterior vitrectomy performed, whereas the remaining two were cured by neodymium-YAG laser disruption of the anterior hyaloid. In these two cases, the posterior capsule remained intact. Neodymium-YAG laser vitreolysis should be the first step in the management of these cases because of its safety compared with open surgery.