Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Oct;69(10):2785-2797.
doi: 10.1109/TUFFC.2022.3189338. Epub 2022 Sep 27.

Fine Pitch Flexible Printed Circuit Board Patterning for Miniaturized Endoscopic MicroUltrasound Arrays

Fine Pitch Flexible Printed Circuit Board Patterning for Miniaturized Endoscopic MicroUltrasound Arrays

Carlos-Felipe Roa et al. IEEE Trans Ultrason Ferroelectr Freq Control. 2022 Oct.

Abstract

Microultrasound (micro-US) has become an invaluable tool for preclinical research and in emerging applications in clinical diagnosis and treatment guidance. Several such applications can benefit from arrays with a small footprint and endoscopic form factor. However, critical challenges arise in making electrical connections to array elements in such spatial constraints. In this work, we describe a method to pattern a high-density flexible circuit cabling on a copper-on polyimide film, using laser ablation of a polymer resist and wet etching, and then demonstrate a connection to a micro-US array. We investigate laser ablation process parameters and evaluate the ability to consistently pattern continuous copper traces. A minimum 30- [Formula: see text] pitch was achieved with 5- [Formula: see text]-wide electrode lines, and continuity of a 5-m-long trace is demonstrated. A flexible circuit with 30-mm-long traces with 30- [Formula: see text] line and 30- [Formula: see text] space before fan-out was fabricated to connect in an interleaved manner to a 32-element array with 30- [Formula: see text] element pitch. Metal deposition and laser ablation were used to connect and pattern the element electrodes to the copper traces of the flexible circuit. Electrical and acoustic measurements show good yield and consistent impedance across channels. Element pulse-echo tests demonstrated device functionality; the two-way pulse had 43-MHz center frequency and 40% fractional bandwidth (-6 dB). The proposed manufacturing methods facilitate the prototyping and fabrication of flexible endoscopic or small-footprint micro-US devices.

PubMed Disclaimer

Publication types

LinkOut - more resources