Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 May-Jun;38(5):1238-1242.
doi: 10.12669/pjms.38.5.5207.

Reliability of hand-held dynamometer in measuring gluteus medius isometric muscle strength in healthy population

Affiliations

Reliability of hand-held dynamometer in measuring gluteus medius isometric muscle strength in healthy population

Rabail Rani Soomro et al. Pak J Med Sci. 2022 May-Jun.

Abstract

Objectives: To determine the inter-rater and intra-rater reliability of the hand-held dynamometer in measuring isometric gluteus medius muscle strength in asymptomatic healthy population.

Methods: It was a cross sectional study conducted at the department of physiotherapy, Sindh Institute of Physical Medicine and Rehabilitation from March 2021 to April 2021. Thirty healthy subjects aged 18 to 25 years of both sexes and no previous or current complaints of hip or knee pain were included through non-probability purposive sampling technique. The strength of the unilateral isometric gluteus medius muscle was measured using a hand-held dynamometer by two raters at the same day and a week later. Pearson Correlation coefficient was calculated to see the relationship of muscle strength measured by each rater within and between day's sessions. Intra-class correlation was calculated with 95% confidence interval and Standard error of measurements using reliability analysis.

Results: In the present study there were thirty participants studied by two raters, the mean age of participants was 21.53 (SD=±1.40) years, the mean BMI was 24.05 (SD=±1.12) kg/m2 and 70% participants were female and 30% were males. This study showed the mean muscle measurement of participants within days was 12.92 (SD=±0.94), with intra-class correlation ICC (2,2) 0.94 and SEM 0.12 and mean muscle measurement of patients between days was 12.99 (SD=±0.91), with intra-class correlation ICC (2,2) 0.90 and SEM 0.12..

Conclusion: Hand-held dynamometer has shown excellent inter-rater and intra-rater reliability in measuring isometric strength of Gluteus Medius muscle among healthy population. It is convenient to be used in clinical settings and can be a useful outcome tool to assess strength in interventional studies.

Keywords: Hand-held dynamometer; Isometric strength; Reliability.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest: None.

Similar articles

Cited by

References

    1. Jackson SM, Cheng MS, Smith AR, Jr, Kolber MJ. Intrarater reliability of hand held dynamometry in measuring lower extremity isometric strength using a portable stabilization device. Musculoskelet Sci Pract. 2017;27:137–141. doi:10.1016/j.math.2016.07.010. - PubMed
    1. Jeon IC. Comparisons of test-retest reliability of strength measurement of gluteus medius strength between break and make test in subjects with pelvic drop. J Kor Phys Ther. 2019;31(3):147–150. doi:10.18857/jkpt.2019.31.3.147.
    1. Zaidi F, Ahmed I. Effectiveness of muscle energy technique as compared to Maitland mobilization for the treatment of chronic sacroiliac joint dysfunction. J Pak Med Assoc. 2020;70(10):1693–1697. doi:10.5455/JPMA.43722. - PubMed
    1. Cooper NA, Scavo KM, Strickland KJ, Tipayamongkol N, Nicholson JD, Bewyer DC, et al. Prevalence of gluteus medius weakness in people with chronic low back pain compared to healthy controls. Euro Spine J. 2016;25(4):1258–1265. doi:10.1007/s00586-015-4027-6. - PubMed
    1. Baik SM, Cynn HS, Kim SH. Understanding and Exercise of Gluteus Medius Weakness:A Systematic Review. Phys Ther Korea. 2021;28(1):27–35. doi:10.12674/ptk.2021.28.1.27.

LinkOut - more resources