Xenon contrast enhancement in computed body tomography
- PMID: 358251
- DOI: 10.1148/129.1.219
Xenon contrast enhancement in computed body tomography
Abstract
Xenon has been investigated as a contrast medium for conventional radiography, and in vitro as a contrast medium for computed tomography. The authors evaluated xenon contrast enhancement in vivo for CT body scanning. Nine healthy subjects had CT scans before and during xenon inhalation. Concentrations of xenon used varied from 10--50%. Consistent useful changes in attenuation from inhaled xenon were found in the lung but not in abdominal organs. Lung attenuation varied linearly with the xenon concentration in the inhaled gas. Inhalation of xenon concentrations greater than 30% resulted in side effects. Further studies are required to demonstrate whether xenon contrast enhancement is of diagnostic value in computed tomography.
Similar articles
-
A clinical evaluation of xenon enhancement for computed tomography.Invest Radiol. 1980 Nov-Dec;15(6 Suppl):S160-3. doi: 10.1097/00004424-198011001-00036. Invest Radiol. 1980. PMID: 7203917
-
Krypton for computed tomography lung ventilation imaging: preliminary animal data.Invest Radiol. 2015 May;50(5):305-8. doi: 10.1097/RLI.0000000000000130. Invest Radiol. 2015. PMID: 25551823
-
Worsening respiratory function in mechanically ventilated intensive care patients: feasibility and value of xenon-enhanced dual energy CT.Eur J Radiol. 2013 Mar;82(3):557-62. doi: 10.1016/j.ejrad.2012.10.029. Epub 2012 Dec 10. Eur J Radiol. 2013. PMID: 23238360 Clinical Trial.
-
Local cerebral blood flow by xenon-enhanced CT: current status, potential improvements, and future directions.Cerebrovasc Brain Metab Rev. 1989 Spring;1(1):68-86. Cerebrovasc Brain Metab Rev. 1989. PMID: 2701371 Review.
-
Progress in cerebrovascular disease: local cerebral blood flow by xenon enhanced CT.Stroke. 1982 Nov-Dec;13(6):750-8. doi: 10.1161/01.str.13.6.750. Stroke. 1982. PMID: 6755813 Review.
Cited by
-
New insights on COPD imaging via CT and MRI.Int J Chron Obstruct Pulmon Dis. 2007;2(3):301-12. Int J Chron Obstruct Pulmon Dis. 2007. PMID: 18229568 Free PMC article. Review.
-
Detection of demyelinated plaques with xenon-enhanced computed tomography.Neuroradiology. 1980 Dec;20(4):181-3. doi: 10.1007/BF00336679. Neuroradiology. 1980. PMID: 6970345
-
Physiologic implications of adding small amounts of carbon dioxide to the gas mixture during inhalation of xenon.Neuroradiology. 1992;34(4):297-300. doi: 10.1007/BF00588185. Neuroradiology. 1992. PMID: 1528437
-
Optimization of dual-energy xenon-computed tomography for quantitative assessment of regional pulmonary ventilation.Invest Radiol. 2013 Sep;48(9):629-37. doi: 10.1097/RLI.0b013e31828ad647. Invest Radiol. 2013. PMID: 23571834 Free PMC article.
-
Ventilation/Perfusion Relationships and Gas Exchange: Measurement Approaches.Compr Physiol. 2020 Jul 8;10(3):1155-1205. doi: 10.1002/cphy.c180042. Compr Physiol. 2020. PMID: 32941684 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources