Comprehensive virtual orthognathic planning concept in surgery-first patients
- PMID: 35835610
- DOI: 10.1016/j.bjoms.2022.04.008
Comprehensive virtual orthognathic planning concept in surgery-first patients
Abstract
The surgery-first concept is becoming increasingly popular in orthognathic surgery since it offers major advantages such as a reduction of treatment duration and an increase in patient satisfaction by eliminating phases of presurgical orthodontic decompensation. Here, we present a novel interdisciplinary pathway of a fully virtual orthodontic-surgical planning concept in a surgery-first setting using a 3D-printed cutting guide and a customised maxillary implant for the Le Fort I osteotomy as well as a CAD/CAM-based stereolithographic final splint. Patient data from cone-beam computed tomography of the skull and a full arch dental scan were processed using the OnyxCeph3TM software (Image Instruments). A mutual computer-aided surgical simulation was conducted by the orthodontist and the oral and maxillofacial surgeon to determine the three-dimensional maxillary and mandibular movements. In a separate virtual planning session, the surgeon designed a customised maxillary guide and implant for precise intraoperative transfer (Geomagic Freeform Plus software, 3DSystems). A 3D-printed CAD/CAM-based final splint was fabricated by the orthodontist and used for accurate mandibular repositioning. We established a comprehensive virtual interdisciplinary orthognathic workflow and successfully applied this concept with a high level of accuracy in a series of surgery-first patients with different types of dentofacial anomalies. This novel fully computer-based pathway offers a high potential to improve the outcomes of orthognathic surgery and reduce total treatment time in the management of the orthognathic patient.
Keywords: CAD/CAM; Computer-aided surgical simulation; Customised implant; Orthognathic surgery; Surgery-first approach.
Copyright © 2022. Published by Elsevier Ltd.
Conflict of interest statement
Conflict of interest We have no conflicts of interest.
Similar articles
-
Accuracy of virtual surgical planning of orthognathic surgery with aid of CAD/CAM fabricated surgical splint-A novel 3D analyzing algorithm.J Craniomaxillofac Surg. 2017 Dec;45(12):1962-1970. doi: 10.1016/j.jcms.2017.07.016. Epub 2017 Jul 29. J Craniomaxillofac Surg. 2017. PMID: 29066041
-
Orthognathic positioning system: intraoperative system to transfer virtual surgical plan to operating field during orthognathic surgery.J Oral Maxillofac Surg. 2013 May;71(5):911-20. doi: 10.1016/j.joms.2012.11.004. Epub 2013 Jan 10. J Oral Maxillofac Surg. 2013. PMID: 23312847
-
RapidSplint: virtual splint generation for orthognathic surgery - results of a pilot series.Comput Aided Surg. 2014;19(1-3):20-8. doi: 10.3109/10929088.2014.887778. Epub 2014 Apr 10. Comput Aided Surg. 2014. PMID: 24720495 Free PMC article.
-
Digital Workflow for Combined Orthodontics and Orthognathic Surgery.Oral Maxillofac Surg Clin North Am. 2020 Feb;32(1):1-14. doi: 10.1016/j.coms.2019.08.004. Epub 2019 Nov 4. Oral Maxillofac Surg Clin North Am. 2020. PMID: 31699582 Review.
-
Patient-Specific Implants in Orthognathic Surgery.Oral Maxillofac Surg Clin North Am. 2023 Feb;35(1):61-69. doi: 10.1016/j.coms.2022.06.004. Epub 2022 Nov 3. Oral Maxillofac Surg Clin North Am. 2023. PMID: 36336593 Review.
Cited by
-
Reverse Engineering Orthognathic Surgery and Orthodontics in Individuals with Cleft Lip and/or Palate: A Case Report.Bioengineering (Basel). 2024 Jul 31;11(8):771. doi: 10.3390/bioengineering11080771. Bioengineering (Basel). 2024. PMID: 39199729 Free PMC article.
-
Volumetric evaluation of osteotomy gap following mandibular bilateral sagittal split osteotomy using a novel semi-automated approach: a pilot study.Clin Oral Investig. 2024 Jun 6;28(7):358. doi: 10.1007/s00784-024-05753-9. Clin Oral Investig. 2024. PMID: 38842694 Free PMC article.
-
Current Trends in Orthognathic Surgery.Medicina (Kaunas). 2023 Nov 30;59(12):2100. doi: 10.3390/medicina59122100. Medicina (Kaunas). 2023. PMID: 38138203 Free PMC article. Review.