Electromechanical potentials in cortical bone--I. A continuum approach
- PMID: 3584151
- DOI: 10.1016/0021-9290(87)90293-4
Electromechanical potentials in cortical bone--I. A continuum approach
Abstract
An electrokinetic model to characterize the electromechanical effect in cortical bone has been developed using the basic principles of the biphasic theory of porous materials and a simple model for permeability and charge distribution for cortical bone. The model is developed analytically in Part I of this paper and is shown to account qualitatively for the principal experimental results reported to date. Part II of this paper concerns experimental analysis of this model, reporting results of low frequency testing of the dynamic characteristics of stress-generated potentials. Quantitative analysis of these results indicates that the microporosity of bone, made up of the channels around the hydroxyapatite encrusting the collagen matrix, is the compartment responsible for the electromechanical effects in fluid-saturated cortical bone. This microporous compartment would seem to be the obvious source of the electrokinetic effect, because it has the greatest surface area in bone and constitutes the rate limiting fluid flow compartment in deformation-induced fluid flow at low frequency.
Similar articles
-
Electromechanical potentials in cortical bone--II. Experimental analysis.J Biomech. 1987;20(3):271-80. doi: 10.1016/0021-9290(87)90294-6. J Biomech. 1987. PMID: 3584152
-
Oscillatory and step response electromechanical phenomena in human and bovine bone.J Biomech. 1990;23(2):127-43. doi: 10.1016/0021-9290(90)90347-6. J Biomech. 1990. PMID: 2179217 Review.
-
Electromechanical potentials in cortical bone (phenomenological approach).Dokl Biochem Biophys. 2003 Sep-Oct;392:268-70. doi: 10.1023/a:1026142830553. Dokl Biochem Biophys. 2003. PMID: 15255200 No abstract available.
-
Deformation-induced hierarchical flows and drag forces in bone canaliculi and matrix microporosity.J Biomech. 1997 Jan;30(1):11-8. doi: 10.1016/s0021-9290(96)00121-2. J Biomech. 1997. PMID: 8970919
-
Electrical effects in bone.J Biomed Eng. 1988 Nov;10(6):515-21. doi: 10.1016/0141-5425(88)90109-4. J Biomed Eng. 1988. PMID: 3070168 Review.
Cited by
-
A fiber matrix model for fluid flow and streaming potentials in the canaliculi of an osteon.Ann Biomed Eng. 1994 May-Jun;22(3):280-92. doi: 10.1007/BF02368235. Ann Biomed Eng. 1994. PMID: 7978549
-
Osteocyte shape and mechanical loading.Curr Osteoporos Rep. 2015 Apr;13(2):61-6. doi: 10.1007/s11914-015-0256-1. Curr Osteoporos Rep. 2015. PMID: 25663071 Free PMC article. Review.
-
Mechanotransduction and the functional response of bone to mechanical strain.Calcif Tissue Int. 1995 Nov;57(5):344-58. doi: 10.1007/BF00302070. Calcif Tissue Int. 1995. PMID: 8564797 Review.
-
An in vivo assessment of muscular activity and the importance of electrical phenomena in bone remodelling.J Anat. 1990 Oct;172:165-75. J Anat. 1990. PMID: 2272901 Free PMC article.
-
Mathematically modeling fluid flow and fluid shear stress in the canaliculi of a loaded osteon.Biomed Eng Online. 2016 Dec 28;15(Suppl 2):149. doi: 10.1186/s12938-016-0267-x. Biomed Eng Online. 2016. PMID: 28155688 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources