Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Nov;307(Pt 1):135705.
doi: 10.1016/j.chemosphere.2022.135705. Epub 2022 Jul 14.

Variability of urinary biomarkers of neonicotinoid insecticides in Chinese population: Implications for human exposure assessment

Affiliations

Variability of urinary biomarkers of neonicotinoid insecticides in Chinese population: Implications for human exposure assessment

Feixue Li et al. Chemosphere. 2022 Nov.

Abstract

Neonicotinoids are a class of the most widely used insecticides worldwide with a short biological half-life. The levels of neonicotinoids and their metabolites in urine have been detected as biomarkers for human exposure assessment. To understand the reliability of a single measurement of urinary neonicotinoid biomarkers in representing a true longer-term average exposure, in this study we evaluated the temporal variability of 14 neonicotinoids and/or their metabolites over one year in 114 Chinese young adults. The detection rates of 14 neonicotinoid biomarkers ranged from 18% to 100%. The intraclass correlation coefficients (ICCs) of most neonicotinoid biomarkers indicated poor (ICC <0.4) reproducibility in spot urine samples during 1-week, 1-month, or 1-year periods, except for 5-hydroxy-imidacloprid (5-OH-IMI) within 1-week showing fair to good reproducibility (ICC = 0.40). Log-transformed 5-OH-IMI, dinotefuran, 1-methyl-3-(tetrahydro-3-furylmethyl) urea, N-desmethyl-acetamiprid, and N-desmethyl-thiamethoxam required a minimum of 2-4 spot urine samples over one year to obtain a reliable exposure evaluation. Using two or three spot urine samples to categorize the "true" exposure of the highest tertile indicated the higher specificities (0.60-1.00) than the sensitivities (0.24-0.93). We recommend that at least 2-4 spot urine samples are used to assess 1-year neonicotinoid exposure and seasonal variations should be considered when scheduling urine sample collection. This study provides a reference for appropriate sampling method and research design for the exposure assessment of neonicotinoids in biomonitoring and epidemiological studies.

Keywords: Biomarker; Exposure assessment; Insecticide; Neonicotinoid; Urine; Variability.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Similar articles

Cited by

LinkOut - more resources