The comparative accuracy of pooled vs. individual blood culture sampling methods for diagnosis of catheter-related bloodstream infection
- PMID: 35843933
- PMCID: PMC9290260
- DOI: 10.1186/s12879-022-07605-x
The comparative accuracy of pooled vs. individual blood culture sampling methods for diagnosis of catheter-related bloodstream infection
Abstract
Background: Catheter-related bloodstream infection (CRBSI) is associated with increased morbidity, mortality, and cost of treatment in critically ill patients. A differential time to positivity (DTP) of 120 min or more between blood cultures obtained through the catheter vs. peripheral vein is an indicator of CRBSI with high sensitivity and specificity. However, it is no clear whether pooled sampling would be as efficient as individual sampling in order to reduce costs, contamination, or anemia.
Methods: This was a prospective diagnostic study conducted at the medical ICU and semi-ICU of Khon Kaen University's Srinagarind Hospital in Thailand from May 2020 to November 2021. Fifty patients with triple-lumen central venous catheters (CVCs) who were clinically suspected of CRBSI were enrolled. 15 mL of blood was drawn through each catheter lumen, 10 mL of which was inoculated into three blood culture bottles, and the remaining 5 mL was pooled into a single bottle. Sensitivity, specificity, accuracy, and time to positivity of the pooled blood cultures were calculated using individual blood cultures as a reference.
Results: Of the 50 patients enrolled, 14 (28%) were diagnosed with CRBSI, 57.9% of whom were infected with gram-negative bacteria as the causative pathogen (57.9%). Extensively drug-resistant (XDR) Klebsiella pneumoniae was the most common organism. Sensitivity and specificity of the pooled blood sampling method were 69.23% (95% CI [0.44-0.94]) and 97.3% (95% CI [0.92-1.02]), respectively. The area under the ROC curve (AUC) was 0.83 (95% CI [0.68-0.99]). A paired T-Test to compare time to positivity of the pooled blood bottle and the first positive culture from the individual bottles indicated statistical significance (14.9 and 12.4 h, respectively). The mean difference was 2.5 [0.9-4.1] h, with a 95% CI and a p-value of 0.006.
Conclusion: Pooled blood sampling results in a lower sensitivity and longer time to positivity for CRBSI diagnosis in patients with triple-lumen CVCs than individual lumen sampling. Trial registration Retrospectively registered at Thai Clinical Trials Registry. The study was reviewed and approved on 08/03/2022. TCTR identification number is TCTR20220308002.
Keywords: Catheter-related bloodstream infection (CRBSI); Differential time to positivity; Hospital-acquired infections; Individual blood culture; Infection control; Pooled blood culture.
© 2022. The Author(s).
Conflict of interest statement
The authors declare that they have no competing interests.
Figures
Similar articles
-
[The value of differential time to positivity of blood cultures in diagnosis of catheter-related bloodstream infection in patients with solid tumors in intensive care unit].Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2015 Jun;27(6):489-93. doi: 10.3760/cma.j.issn.2095-4352.2015.06.014. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue. 2015. PMID: 26049189 Chinese.
-
Diagnosis of catheter-related bloodstream infection in neonates: a study on the value of differential time to positivity of paired blood cultures.Pediatr Crit Care Med. 2007 Sep;8(5):470-5. doi: 10.1097/01.PCC.0000282156.44533.D1. Pediatr Crit Care Med. 2007. PMID: 17693911
-
Differential time to positivity: vascular catheter drawn cultures for the determination of catheter-related bloodstream infection.Scand J Infect Dis. 2012 Oct;44(10):721-5. doi: 10.3109/00365548.2012.678883. Epub 2012 Jun 10. Scand J Infect Dis. 2012. PMID: 22681307
-
High success rate in salvage of catheter-related bloodstream infections due to Staphylococcus aureus, on behalf of project group of Italian society of nephrology.J Vasc Access. 2020 May;21(3):336-341. doi: 10.1177/1129729819875323. Epub 2019 Sep 12. J Vasc Access. 2020. PMID: 31512986 Review.
-
Clinical usefulness of catheter-drawn blood samples and catheter tip cultures for the diagnosis of catheter-related bloodstream infections in neonatology: A systematic review.Am J Infect Control. 2018 Jan;46(1):81-87. doi: 10.1016/j.ajic.2017.06.030. Epub 2017 Aug 12. Am J Infect Control. 2018. PMID: 28807426
Cited by
-
Direct Disk Diffusion Testing and Antimicrobial Stewardship for Gram-Negative Bacteremia in the Context of High Multidrug Resistance.Antibiotics (Basel). 2025 Jul 19;14(7):726. doi: 10.3390/antibiotics14070726. Antibiotics (Basel). 2025. PMID: 40724027 Free PMC article.
References
-
- Hammarskjöld F, Berg S, Hanberger H, Taxbro K, Malmvall B-E. Sustained low incidence of central venous catheter-related infections over six years in a Swedish hospital with an active central venous catheter team. Am J Infect Control. 2014;42(2):122–128. doi: 10.1016/j.ajic.2013.09.023. - DOI - PubMed
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources