Continuous neonatal evaluation in the delivery room by pulse oximetry
- PMID: 3585439
- DOI: 10.1007/BF00858357
Continuous neonatal evaluation in the delivery room by pulse oximetry
Abstract
The pulse oximeter, a noninvasive and continuous monitor of arterial oxygenation that is reliable in adults, children, and infants, was evaluated for use in neonates in the delivery suite. One hundred newborn infants, weighing 850 to 5,230 g each, delivered vaginally or by cesarean section with general or epidural anesthesia were studied. After delivery, each infant was placed in a radiant warmer, and a pulse oximetry probe was placed on the right hand. Hemoglobin saturation was then recorded for 15 minutes. Initial pulse oximetry values were obtained in less than one minute after cord clamping in 43% of infants, less than two minutes in 81%, and less than three minutes in 98%. Average arterial oxygen saturation was 59% at 1 minute (43 infants), 68% at 2 minutes (81), 82% at 5 minutes (98), and 90% at 15 minutes (91). Oxygen saturation was less than 30% in 12 neonates and less than 50% in 26 neonates at some time during the 15-minute monitoring period. Oxygen saturation did not differ significantly between neonates delivered vaginally or by cesarean section, regardless of the presence or type of anesthetic used. Arterial oxygen saturation measured by pulse oximetry showed a statistically significant relationship when compared with the traditional Apgar scoring system. Pulse oximetry was found to be very useful in objectively judging the adequacy of resuscitative efforts, as well as in identifying children who had marked arterial desaturation during the early neonatal period.
Similar articles
-
Evaluation of oxygen saturation monitoring by pulse oximetry in neonates in the delivery system.Can J Anaesth. 1991 Nov;38(8):985-8. doi: 10.1007/BF03008616. Can J Anaesth. 1991. PMID: 1752021
-
Pulse oximetry: an alternative method for the assessment of oxygenation in newborn infants.Pediatrics. 1987 Apr;79(4):524-8. Pediatrics. 1987. PMID: 2434911
-
Pulse oximetry in the newborn: is the left hand pre- or post-ductal?BMC Pediatr. 2010 May 21;10:35. doi: 10.1186/1471-2431-10-35. BMC Pediatr. 2010. PMID: 20492689 Free PMC article.
-
Pulse oximetry: a review of the theory, accuracy, and clinical applications.Obstet Gynecol. 1989 Sep;74(3 Pt 2):541-6. Obstet Gynecol. 1989. PMID: 2668828 Review.
-
Advanced Uses of Pulse Oximetry for Monitoring Mechanically Ventilated Patients.Anesth Analg. 2017 Jan;124(1):62-71. doi: 10.1213/ANE.0000000000001283. Anesth Analg. 2017. PMID: 27183375 Review.
Cited by
-
Pulse oximetry.J Clin Monit. 1989 Jan;5(1):37-62. doi: 10.1007/BF01618369. J Clin Monit. 1989. PMID: 2647912 Review.
-
Oxygen saturation trends in the first hour of life in healthy full-term neonates born at moderate altitude.Pak J Med Sci. 2013 Jul;29(4):903-6. doi: 10.12669/pjms.294.3848. Pak J Med Sci. 2013. PMID: 24353656 Free PMC article.
-
Normal oxygen saturation trend in healthy term newborns within 30 minutes of birth.Indian J Pediatr. 2011 Jul;78(7):817-20. doi: 10.1007/s12098-011-0405-1. Epub 2011 Mar 17. Indian J Pediatr. 2011. PMID: 21409523
-
Correlation of pulse oximetry and apgar scoring in the normal newborns.J Clin Neonatol. 2013 Jan;2(1):20-4. doi: 10.4103/2249-4847.109241. J Clin Neonatol. 2013. PMID: 24027740 Free PMC article.
-
Who needs pulse oximetry?Br Med J (Clin Res Ed). 1988 Mar 5;296(6623):658-9. doi: 10.1136/bmj.296.6623.658. Br Med J (Clin Res Ed). 1988. PMID: 3128357 Free PMC article. No abstract available.