Comparative analysis on intaglio surface trueness, wear volume loss of antagonist, and fracture resistance of full-contour monolithic zirconia crown for single-visit dentistry under simulated mastication
- PMID: 35855321
- PMCID: PMC9259349
- DOI: 10.4047/jap.2022.14.3.173
Comparative analysis on intaglio surface trueness, wear volume loss of antagonist, and fracture resistance of full-contour monolithic zirconia crown for single-visit dentistry under simulated mastication
Abstract
Purpose: This analysis aimed to evaluate the intaglio surface trueness, antagonist's wear volume loss, and fracture resistance of full-contour crowns of (Y, Nb)-stabilized fully-sintered zirconia (FSZ), 4 mol% or 5 mol% yttria-stabilized partially sintered zirconia (4YZ or 5YZ) with high-speed sintering.
Materials and methods: A total of 42 zirconia crowns were separated into three groups: FSZ, 4YZ, and 5YZ (n = 14). The intaglio surface trueness of the crowns was evaluated at the inner surface, occlusal, margin, and axial areas and reported as root-mean-square, positive and negative average deviation. Half of the specimens were aged for 120,000 cycles in the chewing simulator, and the wear volume loss of antagonist was measured. Before and after chewing, the fracture load was measured for each group. The trueness values were analyzed with Welch's ANOVA, and the wear volume loss with the Kruskal-Wallis tests. Effect of the zirconia type and aging on fracture resistance of crowns was tested using two-way ANOVA.
Results: The intaglio surface trueness measured at four different areas of the crown was less than 50 µm, regardless of the type of zirconia. No significant P in wear volume loss of antagonists were detected among the groups (P > .05). Both the type of zirconia and aging showed statistically significant effects on fracture resistance (P < .05).
Conclusion: The full-contour crowns of FSZ as well as 4YZ or 5YZ with high-speed sintering were clinically acceptable, in terms of intaglio surface trueness, antagonist's wear volume loss, and fracture resistance after simulated mastication.
Keywords: Fracture resistance; Fully-sintered zirconia; High-speed sintering; Intaglio surface trueness; Wear volume loss.
© 2022 The Korean Academy of Prosthodontics.
Figures



Similar articles
-
Evaluation of intaglio surface trueness, wear, and fracture resistance of zirconia crown under simulated mastication: a comparative analysis between subtractive and additive manufacturing.J Adv Prosthodont. 2022 Apr;14(2):122-132. doi: 10.4047/jap.2022.14.2.122. Epub 2022 Apr 27. J Adv Prosthodont. 2022. PMID: 35601347 Free PMC article.
-
Trueness of the Inner Surface of Monolithic Crowns Fabricated by Milling of a Fully Sintered (Y, Nb)-TZP Block in Chairside CAD-CAM System for Single-visit Dentistry.Materials (Basel). 2019 Oct 5;12(19):3253. doi: 10.3390/ma12193253. Materials (Basel). 2019. PMID: 31590370 Free PMC article.
-
High-speed sintering on monolithic zirconia: Effects on surface and antagonist wear in vitro.J Prosthodont. 2025 Jun 6. doi: 10.1111/jopr.14083. Online ahead of print. J Prosthodont. 2025. PMID: 40478889
-
Effect of maximum support attachment angle on intaglio surface trueness of anatomic contour monolithic prostheses manufactured by digital light processing and zirconia suspension.J Prosthet Dent. 2023 Mar;129(3):478-485. doi: 10.1016/j.prosdent.2022.12.003. Epub 2023 Jan 6. J Prosthet Dent. 2023. PMID: 36621357
-
Wear in Antagonist Teeth Produced by Monolithic Zirconia Crowns: A Systematic Review and Meta-Analysis.J Clin Med. 2020 Apr 2;9(4):997. doi: 10.3390/jcm9040997. J Clin Med. 2020. PMID: 32252404 Free PMC article. Review.
Cited by
-
Effect of exposure energy dose on lateral resolution and flexural strength of three-dimensionally printed dental zirconia.J Adv Prosthodont. 2023 Oct;15(5):248-258. doi: 10.4047/jap.2023.15.5.248. Epub 2023 Oct 26. J Adv Prosthodont. 2023. PMID: 37936835 Free PMC article.
-
Feasibility of software-based assessment for automated evaluation of tooth preparation for dental crown by using a computational geometric algorithm.Sci Rep. 2023 Jul 22;13(1):11847. doi: 10.1038/s41598-023-39089-3. Sci Rep. 2023. PMID: 37481612 Free PMC article.
References
-
- Schriwer C, Skjold A, Gjerdet NR, Øilo M. Monolithic zirconia dental crowns. Internal fit, margin quality, fracture mode and load at fracture. Dent Mater. 2017;33:1012–1020. - PubMed
-
- Denry I, Kelly JR. State of the art of zirconia for dental applications. Dent Mater. 2008;24:299–307. - PubMed
-
- Antón X, Stawarczyk B, Reymus M, Joda T, Liebermann A. Impact of high-speed sintering on accuracy and fit of 4 mol% yttria-stabilized tetragonal zirconia polycrystals (4Y-TZPs) Int J Prosthodont. 2021;34:775–783. - PubMed
-
- Jansen JU, Lümkemann N, Letz I, Pfefferle R, Sener B, Stawarczyk B. Impact of high-speed sintering on translucency, phase content, grain sizes, and flexural strength of 3Y-TZP and 4Y-TZP zirconia materials. J Prosthet Dent. 2019;122:396–403. - PubMed
LinkOut - more resources
Full Text Sources