Determination of E-modulus of cancellous bone derived from human humeri and validation of plotted single trabeculae: Development of a standardized humerus bone model
- PMID: 35855729
- PMCID: PMC9287625
- DOI: 10.1016/j.jor.2022.07.003
Determination of E-modulus of cancellous bone derived from human humeri and validation of plotted single trabeculae: Development of a standardized humerus bone model
Abstract
Background: Evaluation of the mechanical behavior of the microstructure of cancellous bone seems important for the understanding of the mechanical behavior of bone. Prevention and treatment of fragility fractures due to osteoporosis is a major challenge according to ageing population. A bone model might help to assess fracture risk. Measurement of single trabeculae of bone should give further information compared with bone densitometry alone. This study measures the mechanical properties of single cancellous trabeculae derived from human proximal humerus.
Methods: 34 single trabeculae dissected from human humeral heads were measured and evaluated mechanically. Trabeculae were fixed on microscope slides and geometrical data were reported during axial rotation of the specimens to measure the transverse section using computer aided design (CAD). The samples were subjected to a two-point bending test and were loaded with a measure-stamp at a defined distance. Force and deflection were measured by high-resolution sensors. The E-modulus was then calculated in combination with finite elements method simulation (FEM), using the previously obtained CAD-Data.
Results: The average E-modulus from 34 valid measurements of human humeral trabeculae was 1678 MPa with a range from 829 to 3396 MPa, which is consistent with existing literature. The planned additional validation of the measurement method using manufactured three-dimensional synthetic trabeculae with known mechanical properties showed an average elastic modulus of single trabeculae of 51.5 MPa, being two dimensions lower than the value reported in the datasheet of the plastic.
Conclusion: This newly developed, time and cost-efficient procedure allows the measurement of E-modulus in single trabeculae. Measurement of mechanic parameters of single trabeculae might give insights on mechanic behavior of bone and be relevant for the research of systemic bone diseases, complementing the existing data on bone-mineral-density. Further examination of single trabeculae of human cancellous bone should give an insight on the mechanical behavior of bone also considering systemic bone diseases.
Keywords: E-modulus; Fracture; Mechanic properties; Osteoporosis; Single bone trabecula; Synthetic cancellous bone.
© 2022 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.
Conflict of interest statement
None.
Figures






Similar articles
-
Measuring Young's modulus of single trabeculae in cancellous bone using a two-point bending test.Clin Biomech (Bristol). 2023 Feb;102:105875. doi: 10.1016/j.clinbiomech.2023.105875. Epub 2023 Jan 5. Clin Biomech (Bristol). 2023. PMID: 36634601
-
Three-dimensional morphometric properties of rod- and plate-like trabeculae in adolescent cancellous bone.J Orthop Translat. 2017 Nov 13;12:26-35. doi: 10.1016/j.jot.2017.10.001. eCollection 2018 Jan. J Orthop Translat. 2017. PMID: 29662776 Free PMC article.
-
Microstructure Determines Apparent-Level Mechanics Despite Tissue-Level Anisotropy and Heterogeneity of Individual Plates and Rods in Normal Human Trabecular Bone.J Bone Miner Res. 2021 Sep;36(9):1796-1807. doi: 10.1002/jbmr.4338. Epub 2021 Jun 3. J Bone Miner Res. 2021. PMID: 33989436
-
Micro-cantilever bending for elastic modulus measurements of a single trabecula in cancellous bone.J Biomech. 2016 Dec 8;49(16):4124-4127. doi: 10.1016/j.jbiomech.2016.10.016. Epub 2016 Oct 18. J Biomech. 2016. PMID: 27793405
-
Young's modulus of trabecular bone at the tissue level: A review.Acta Biomater. 2018 Sep 15;78:1-12. doi: 10.1016/j.actbio.2018.08.001. Epub 2018 Aug 4. Acta Biomater. 2018. PMID: 30081232 Review.
Cited by
-
Correlation between Malocclusion and Mandibular Fractures: An Experimental Study Comparing Dynamic Finite Element Models and Clinical Case Studies.Bioengineering (Basel). 2024 Mar 12;11(3):274. doi: 10.3390/bioengineering11030274. Bioengineering (Basel). 2024. PMID: 38534548 Free PMC article.
-
Anisotropy, Anatomical Region, and Additional Variables Influence Young's Modulus of Bone: A Systematic Review and Meta-Analysis.JBMR Plus. 2023 Oct 31;7(12):e10835. doi: 10.1002/jbm4.10835. eCollection 2023 Dec. JBMR Plus. 2023. PMID: 38130752 Free PMC article. Review.
References
-
- Lill H., Scheibel M., Voigt C., editors. Die Proximale Humerusfraktur. Springer Berlin Heidelberg; Berlin, Heidelberg: 2014.
LinkOut - more resources
Full Text Sources
Miscellaneous