Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2023 Apr;17(2):303-312.
doi: 10.1007/s11701-022-01445-2. Epub 2022 Jul 21.

Lower vs standard pressure pneumoperitoneum in robotic-assisted radical prostatectomy: a systematic review and meta-analysis

Affiliations
Meta-Analysis

Lower vs standard pressure pneumoperitoneum in robotic-assisted radical prostatectomy: a systematic review and meta-analysis

Omar El-Taji et al. J Robot Surg. 2023 Apr.

Abstract

Robotic-assisted laparoscopic radical prostatectomy (RARP) has been traditionally performed at a pneumoperitoneum insufflation pressure of 12-15 mmHg. This meta-analysis and systematic review aims to assess the current evidence comparing lower to standard pressure pneumoperitoneum in RARP. Systematic searches of MEDLINE, COCHRANE, SCOPUS and EMBASE were performed to identify articles published up until November 2021 comparing lower pressure with standard pressure pneumoperitoneum in RARP. Standard pressure was defined as > 12 mmHg and lower pressure ≤ 12 mmHg. Estimated blood loss, length of operation, length of hospital stay, post-operative ileus, 30-day readmissions, Clavien-Dindo complications and rate of positive surgical margins were extracted as endpoints of interest. Our searches identified 165 abstracts of which 4 articles with 1319 patients were eligible. Cumulative analysis demonstrated reduced length of stay when a lower pressure was used: WMD - 0.23 (- 0.45 to - 0.02) days (p = 0.03) as well as a reduced rate of post-operative ileus: OR 0.41 (0.22 to 0.77) (p = 0.006). There was no significant increase in length of operation WMD - 1.79 (- 15.96 to 12.38) (p = 0.8), estimated blood loss WMD - 2.89 (- 29.41 to 23.62) (p = 0.83), 30-day readmissions or positive surgical margins OR 1.04 (0.78 to 1.38) (p = 0.81) and RD - 0.01 (- 0.04 to 0.01) (p = 0.3) when using a lower pressure. We have demonstrated reduced length of stay and rates of post-operative ileus, when performing RARP at a lower pressure without a significant increase in length of operation, estimated blood loss, positive surgical margins or complications. The recommendation to use lower pressure pneumoperitoneum is moderate to weak and more randomised control trials are required to validate these results.

Keywords: Clinical outcomes; Lower pressure; Pneumoperitoneum; Robotic-assisted laparoscopic radical prostatectomy.

PubMed Disclaimer

References

    1. Abbou CC, Hoznek A, Salomon L et al (2001) Laparoscopic radical prostatectomy with a remote controlled robot. J Urol 165:1964–1966 - DOI - PubMed
    1. Neudecker J, Sauerland S, Bergamaschi R et al (2002) The European Association for Endoscopic Surgery clinical practice guideline on the pneumoperitoneum for laparoscopic surgery. Surg Endosc 16(7):1121–1143 - DOI - PubMed
    1. Ploussard G (2018) Robotic surgery in urology: facts and reality. What are the real advantages of robotic approaches for prostate cancer patients? Curr Opin Urol 28(2):153–158 - DOI - PubMed
    1. Taura P, Lopez A, Lacy AM et al (1998) Prolonged pneumoperitoneum at 15 mmHg causes lactic acidosis. Surg Endosc 12:198–201 - DOI - PubMed
    1. Kashtan J, Green JF, Parsons EQ, Holcroft JW (1981) Hemodynamic effects of increased abdominal pressure. J Surg Res 30:249–255 - DOI - PubMed

LinkOut - more resources