Learning low-dose CT degradation from unpaired data with flow-based model
- PMID: 35880375
- DOI: 10.1002/mp.15886
Learning low-dose CT degradation from unpaired data with flow-based model
Abstract
Background: There has been growing interest in low-dose computed tomography (LDCT) for reducing the X-ray radiation to patients. However, LDCT always suffers from complex noise in reconstructed images. Although deep learning-based methods have shown their strong performance in LDCT denoising, most of them require a large number of paired training data of normal-dose CT (NDCT) images and LDCT images, which are hard to acquire in the clinic. Lack of paired training data significantly undermines the practicability of supervised deep learning-based methods. To alleviate this problem, unsupervised or weakly supervised deep learning-based methods are required.
Purpose: We aimed to propose a method that achieves LDCT denoising without training pairs. Specifically, we first trained a neural network in a weakly supervised manner to simulate LDCT images from NDCT images. Then, simulated training pairs could be used for supervised deep denoising networks.
Methods: We proposed a weakly supervised method to learn the degradation of LDCT from unpaired LDCT and NDCT images. Concretely, LDCT and normal-dose images were fed into one shared flow-based model and projected to the latent space. Then, the degradation between low-dose and normal-dose images was modeled in the latent space. Finally, the model was trained by minimizing the negative log-likelihood loss with no requirement of paired training data. After training, an NDCT image can be input to the trained flow-based model to generate the corresponding LDCT image. The simulated image pairs of NDCT and LDCT can be further used to train supervised denoising neural networks for test.
Results: Our method achieved much better performance on LDCT image simulation compared with the most widely used image-to-image translation method, CycleGAN, according to the radial noise power spectrum. The simulated image pairs could be used for any supervised LDCT denoising neural networks. We validated the effectiveness of our generated image pairs on a classic convolutional neural network, REDCNN, and a novel transformer-based model, TransCT. Our method achieved mean peak signal-to-noise ratio (PSNR) of 24.43dB, mean structural similarity (SSIM) of 0.785 on an abdomen CT dataset, mean PSNR of 33.88dB, mean SSIM of 0.797 on a chest CT dataset, which outperformed several traditional CT denoising methods, the same network trained by CycleGAN-generated data, and a novel transfer learning method. Besides, our method was on par with the supervised networks in terms of visual effects.
Conclusion: We proposed a flow-based method to learn LDCT degradation from only unpaired training data. It achieved impressive performance on LDCT synthesis. Next, we could train neural networks with the generated paired data for LDCT denoising. The denoising results are better than traditional and weakly supervised methods, comparable to supervised deep learning methods.
Keywords: computed tomography; flow-based model; noise synthesis; weakly supervised learning.
© 2022 American Association of Physicists in Medicine.
Similar articles
-
Probabilistic self-learning framework for low-dose CT denoising.Med Phys. 2021 May;48(5):2258-2270. doi: 10.1002/mp.14796. Epub 2021 Mar 17. Med Phys. 2021. PMID: 33621348
-
Unpaired low-dose computed tomography image denoising using a progressive cyclical convolutional neural network.Med Phys. 2024 Feb;51(2):1289-1312. doi: 10.1002/mp.16331. Epub 2023 Mar 10. Med Phys. 2024. PMID: 36841936
-
Weakly supervised low-dose computed tomography denoising based on generative adversarial networks.Quant Imaging Med Surg. 2024 Aug 1;14(8):5571-5590. doi: 10.21037/qims-24-68. Epub 2024 Jul 26. Quant Imaging Med Surg. 2024. PMID: 39144020 Free PMC article.
-
HCformer: Hybrid CNN-Transformer for LDCT Image Denoising.J Digit Imaging. 2023 Oct;36(5):2290-2305. doi: 10.1007/s10278-023-00842-9. Epub 2023 Jun 29. J Digit Imaging. 2023. PMID: 37386333 Free PMC article. Review.
-
A Review of deep learning methods for denoising of medical low-dose CT images.Comput Biol Med. 2024 Mar;171:108112. doi: 10.1016/j.compbiomed.2024.108112. Epub 2024 Feb 15. Comput Biol Med. 2024. PMID: 38387380 Review.
Cited by
-
CT image denoising methods for image quality improvement and radiation dose reduction.J Appl Clin Med Phys. 2024 Feb;25(2):e14270. doi: 10.1002/acm2.14270. Epub 2024 Jan 19. J Appl Clin Med Phys. 2024. PMID: 38240466 Free PMC article. Review.
-
Synthetic CT generation based on CBCT using improved vision transformer CycleGAN.Sci Rep. 2024 May 20;14(1):11455. doi: 10.1038/s41598-024-61492-7. Sci Rep. 2024. PMID: 38769329 Free PMC article.
References
REFERENCES
-
- Brenner DJ, Hall EJ. Computed tomography-an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277-2284.
-
- De González AB, Mahesh M, Kim KP, et al. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Internal Med. 2009;169(22):2071-2077.
-
- Pearce MS, Salotti JA, Little MP, et al. Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet. 2012;380(9840):499-505.
-
- Jin KH, McCann MT, Froustey E, Unser M. Deep convolutional neural network for inverse problems in imaging. IEEE Trans Image Process. 2017;26(9):4509-4522.
-
- Chen H, Zhang Y, Kalra MK, et al. Low-dose CT with a residual encoder-decoder convolutional neural network. IEEE Trans Med Imaging. 2017;36(12):2524-2535.
MeSH terms
Grants and funding
- Chinese Academy of Sciences Special Research Assistant Grant Program
- SKXRC202224/Young S&T Talent Training Program of Guangdong Provincial Association for S&T
- U20A20373/National Natural Science Foundation of China
- 61871374/National Natural Science Foundation of China
- 62071197/National Natural Science Foundation of China
LinkOut - more resources
Full Text Sources
Medical