Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Feb 1;32(2):e11-e14.
doi: 10.1097/IJG.0000000000002080. Epub 2022 Jul 20.

A Novel Tube Insertion Technique for Glaucoma Drainage Device Implantation

Affiliations

A Novel Tube Insertion Technique for Glaucoma Drainage Device Implantation

Abhijit A Mohite et al. J Glaucoma. .

Abstract

Purpose: Early hypotony after non-valved glaucoma drainage device (GDD) implantation for complex glaucomatous eyes with labile aqueous production can lead to significant visual morbidity. We therefore sought to report the early postoperative outcomes of a novel surgical technique that allows atraumatic insertion of non-valved GDDs through a much smaller 25-gauge scleral track, to minimize entry site leakage and improve safety.

Methods: Retrospective case series of 15 consecutive cases undergoing non-valved GDD insertion into the anterior chamber using a previously unreported technique.

Results: All eyes underwent successful GDD insertion using our novel technique, with no intraoperative complications. The mean preoperative intraocular pressures (IOP), at day 1, week 1 and week 3 were 31.4, 22.4, 23.7, and 25.6 mm Hg, respectively. A statistically significant IOP reduction was achieved at day 1, week 1 and week 3 postoperatively ( P <0.05) without any observed leakage at the scleral entry site. One eye (6.7%) with complex panuveitic glaucoma developed early hypotony (5 mm Hg) with shallow choroidal detachments on day 1. This was successfully managed with 1 intracameral ophthalmic viscoelastic device injection given at the slit-lamp and no further intervention.

Conclusions: This novel single needle-docking intraocular insertion manoeuvre is an easily adoptable technique to make GDD insertion through a smaller 25-gauge water-tight scleral track more efficient and less traumatic. The technique reduces scleral distortion and therefore improves surgical safety particularly in eyes with complex secondary glaucoma.

PubMed Disclaimer

Conflict of interest statement

Disclosure: The authors declare no conflict of interest.

References

    1. Molteno CB, Polkinghorne J, Bowbyes. A. The vicryl tie technique for inserting a draining implant in the treatment of secondary glaucoma. Aust NZ J Ophthalmol. 1986;14:343–354.
    1. Egbert PR, Liebert MF. Internal suture occlusion of the Molteno glaucoma implant for the prevention of post-operative hypotony. Opthalmic Surg. 1989;20:53–56.
    1. Siegner SW, Netland PA, Urban RC Jr, et al. Clinical experience with Baerveldt glaucoma drainage implant. Ophthalmology. 1995;102:1298–1307.
    1. Daniel E, Pistilli M, Pujari SS, et al. Risk of hypotony in non-infectious uveitis. Ophthalmology. 2012;119:2377–2385.
    1. Lim KS, Garg A, Cheng J, et al. Comparison of short-term post-operative hypotony rates of 23-gauge vs 25-gauge needles in formation of the scleral tract for Baerveldt Tube insertion into the anterior chamber. J Curr Glaucoma Pract. 2018;12:36–39.