Artificial Intelligence for Radiation Dose Optimization in Pediatric Radiology: A Systematic Review
- PMID: 35884028
- PMCID: PMC9320231
- DOI: 10.3390/children9071044
Artificial Intelligence for Radiation Dose Optimization in Pediatric Radiology: A Systematic Review
Abstract
Radiation dose optimization is particularly important in pediatric radiology, as children are more susceptible to potential harmful effects of ionizing radiation. However, only one narrative review about artificial intelligence (AI) for dose optimization in pediatric computed tomography (CT) has been published yet. The purpose of this systematic review is to answer the question "What are the AI techniques and architectures introduced in pediatric radiology for dose optimization, their specific application areas, and performances?" Literature search with use of electronic databases was conducted on 3 June 2022. Sixteen articles that met selection criteria were included. The included studies showed deep convolutional neural network (CNN) was the most common AI technique and architecture used for dose optimization in pediatric radiology. All but three included studies evaluated AI performance in dose optimization of abdomen, chest, head, neck, and pelvis CT; CT angiography; and dual-energy CT through deep learning image reconstruction. Most studies demonstrated that AI could reduce radiation dose by 36-70% without losing diagnostic information. Despite the dominance of commercially available AI models based on deep CNN with promising outcomes, homegrown models could provide comparable performances. Future exploration of AI value for dose optimization in pediatric radiology is necessary due to small sample sizes and narrow scopes (only three modalities, CT, positron emission tomography/magnetic resonance imaging and mobile radiography, and not all examination types covered) of existing studies.
Keywords: as low as reasonably achievable; computed tomography; convolutional neural network; deep learning; dose reduction; generative adversarial network; image processing; machine learning; medical imaging; noise.
Conflict of interest statement
The author declares no conflict of interest.
Figures
References
-
- Jeon P.H., Kim D., Chung M.A. Estimates of the image quality in accordance with radiation dose for pediatric imaging using deep learning CT: A phantom study; Proceedings of the 2022 IEEE International Conference on Big Data and Smart Computing (BigComp); Daegu, Korea. 17–22 January 2022; pp. 352–356. - DOI
-
- Kim S.H., Seo K., Kang S.H., Bae S., Kwak H.J., Hong J.W., Hwang Y., Kang S.M., Choi H.R., Kim G.Y., et al. Study on feasibility for artificial intelligence (AI) noise reduction algorithm with various parameters in pediatric abdominal radio-magnetic computed tomography (CT) J. Magn. 2017;22:570–578. doi: 10.4283/JMAG.2017.22.4.570. - DOI
-
- Krueger P.C., Ebeling K., Waginger M., Glutig K., Scheithauer M., Schlattmann P., Proquitté H., Mentzel H.J. Evaluation of the post-processing algorithms SimGrid and S-Enhance for paediatric intensive care patients and neonates. Pediatr. Radiol. 2022;52:1029–1037. doi: 10.1007/s00247-021-05279-2. - DOI - PMC - PubMed
Publication types
LinkOut - more resources
Full Text Sources
Miscellaneous