Sentinel Lymph Node Mapping in Breast Cancer Patients Through Fluorescent Imaging Using Indocyanine Green: The INFLUENCE Trial
- PMID: 35894448
- DOI: 10.1097/SLA.0000000000005633
Sentinel Lymph Node Mapping in Breast Cancer Patients Through Fluorescent Imaging Using Indocyanine Green: The INFLUENCE Trial
Abstract
Objective: The aim was to compare the (sentinel) lymph node detection rate of indocyanine green (ICG)-fluorescent imaging versus standard-of-care 99m Tc-nanocoilloid for sentinel lymph node (SLN)-mapping.
Background: The current gold standard for axillary staging in patients with breast cancer is sentinel lymph node biopsy (SLNB) using radio-guided surgery using radioisotope technetium ( 99m Tc), sometimes combined with blue dye. A promising alternative is fluorescent imaging using ICG.
Methods: In this noninferiority trial, we enrolled 102 consecutive patients with invasive early-stage, clinically node-negative breast cancer. Patients were planned for breast conserving surgery and SLNB between August 2020 and June 2021. The day or morning before surgery, patients were injected with 99m Tc-nanocolloid. In each patient, SLNB was first performed using ICG-fluorescent imaging, after which excised lymph nodes were tested with the gamma-probe for 99m Tc-uptake ex vivo, and the axilla was checked for residual 99m Tc-activity. The detection rate was defined as the proportion of patients in whom at least 1 (S)LN was detected with either tracer.
Results: In total, 103 SLNBs were analyzed. The detection rate of ICG-fluorescence was 96.1% [95% confidence interval (95% CI)=90.4%-98.9%] versus 86.4% (95% CI=78.3%-92.4%) for 99m Tc-nanocoilloid. The detection rate for pathological lymph nodes was 86.7% (95% CI=59.5%-98.3%) for both ICG and 99m Tc-nanocoilloid. A median of 2 lymph nodes were removed. ICG-fluorescent imaging did not increase detection time. No adverse events were observed.
Conclusions: ICG-fluorescence showed a higher (S)LN detection rate than 99m Tc-nanocoilloid, and equal detection rate for pathological (S)LNs. ICG-fluorescence may be used as a safe and effective alternative to 99m Tc-nanocoilloid for SLNB in patients with early-stage breast cancer.
Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.
Conflict of interest statement
The authors report no conflicts of interest.
References
-
- Goyal A, Newcombe RG, Chhabra A, et al. Factors affecting failed localisation and false-negative rates of sentinel node biopsy in breast cancer—results of the ALMANAC validation phase. Breast Cancer Res Treat. 2006;99:203–208.
-
- Kedrzycki MS, Leiloglou M, Ashrafian H, et al. Meta-analysis comparing fluorescence imaging with radioisotope and blue dye-guided sentinel node identification for breast cancer surgery. Ann Surg Oncol. 2021;28:3738–3748.
-
- Rao R, Euhus D, Mayo HG, et al. Axillary node interventions in breast cancer: a systematic review. JAMA. 2013;310:1385–1394.
-
- Zavagno G, De Salvo GL, Scalco G, et al. A Randomized clinical trial on sentinel lymph node biopsy versus axillary lymph node dissection in breast cancer: results of the Sentinella/GIVOM trial. Ann Surg. 2008;247:207–213.
-
- Ahmed M, Purushotham AD, Douek M. Novel techniques for sentinel lymph node biopsy in breast cancer: a systematic review. Lancet Oncol. 2014;15:e351–e362.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical