CORR Insights®: Does Kinematic Alignment Increase Polyethylene Wear Compared With Mechanically Aligned Components? A Wear Simulation Study
- PMID: 35901445
- PMCID: PMC9384931
- DOI: 10.1097/CORR.0000000000002305
CORR Insights®: Does Kinematic Alignment Increase Polyethylene Wear Compared With Mechanically Aligned Components? A Wear Simulation Study
Conflict of interest statement
The author certifies that there are no funding or commercial associations (consultancies, stock ownership, equity interest, patent/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted article related to the author or any immediate family members. All ICMJE Conflict of Interest Forms for authors and Clinical Orthopaedics and Related Research® editors and board members are on file with the publication and can be viewed on request.
Comment on
-
Does Kinematic Alignment Increase Polyethylene Wear Compared With Mechanically Aligned Components? A Wear Simulation Study.Clin Orthop Relat Res. 2022 Sep 1;480(9):1790-1800. doi: 10.1097/CORR.0000000000002245. Epub 2022 May 17. Clin Orthop Relat Res. 2022. PMID: 35583549 Free PMC article.
Similar articles
-
Does Kinematic Alignment Increase Polyethylene Wear Compared With Mechanically Aligned Components? A Wear Simulation Study.Clin Orthop Relat Res. 2022 Sep 1;480(9):1790-1800. doi: 10.1097/CORR.0000000000002245. Epub 2022 May 17. Clin Orthop Relat Res. 2022. PMID: 35583549 Free PMC article.
-
PEEK-OPTIMA™ as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study.Proc Inst Mech Eng H. 2016 Nov;230(11):1008-1015. doi: 10.1177/0954411916667410. Epub 2016 Sep 27. Proc Inst Mech Eng H. 2016. PMID: 27637723 Free PMC article.
-
An energy dissipation and cross shear time dependent computational wear model for the analysis of polyethylene wear in total knee replacements.J Biomech. 2014 Mar 21;47(5):1127-33. doi: 10.1016/j.jbiomech.2013.12.017. Epub 2014 Jan 15. J Biomech. 2014. PMID: 24480701
-
Kinematic alignment in total knee arthroplasty.Oper Orthop Traumatol. 2021 Dec;33(6):525-537. doi: 10.1007/s00064-021-00729-4. Epub 2021 Aug 19. Oper Orthop Traumatol. 2021. PMID: 34414467 Review. English.
-
All-polyethylene tibial components in modern total knee arthroplasty.J Am Acad Orthop Surg. 2011 Sep;19(9):527-35. doi: 10.5435/00124635-201109000-00003. J Am Acad Orthop Surg. 2011. PMID: 21885698 Review.
References
-
- Abdel MP, Oussedik S, Parratte S, Lustig S, Haddad FS. Coronal alignment in total knee replacement: historical review, contemporary analysis, and future direction. Bone Joint J. 2014;96:857-862. - PubMed
-
- Cheng CK, Wang XH, Luan YC, et al. Challenges of pre-clinical testing in orthopedic implant development. Med Eng Phys. 2019;72:49-54. - PubMed
-
- International Organization for Standardization. ISO 14243-1. Implants for surgery—wear of total knee-joint prostheses— part 1: loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test. Available at: https://www.iso.org/standard/44262.html. Accessed June 2, 2022.
-
- Wang XH, Dong X, Zhu BZ, et al. A preclinical method for evaluating the kinematics of knee prostheses. Med Eng Phys. 2019;66:84-90. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical