A systematic review on chlorine tolerance among bacteria and standardization of their assessment protocol in wastewater
- PMID: 35906907
- DOI: 10.2166/wst.2022.206
A systematic review on chlorine tolerance among bacteria and standardization of their assessment protocol in wastewater
Abstract
Though chlorine is a cost-effective disinfectant for water and wastewaters, the bacteria surviving after chlorination pose serious public health and environmental problems. This review critically assesses the mechanism of chlorine disinfection as described by various researchers; factors affecting chlorination efficacy; and the re-growth potential of microbial contaminations in treated wastewater post chlorination to arrive at meaningful doses for ensuring health safety. Literature analysis shows procedural inconsistencies in the assessment of chlorine tolerant bacteria, making it extremely difficult to compare the tolerance characteristics of different reported tolerant bacteria. A comparison of logarithmic reduction after chlorination and the concentration-time values for prominent pathogens led to the generation of a standard protocol for the assessment of chlorine tolerance. The factors that need to be critically monitored include applied chlorine doses, contact time, determination of chlorine demands of the medium, and the consideration of bacterial counts immediately after chlorination and in post chlorinated samples (regrowth). The protocol devised here appropriately assesses the chlorine-tolerant bacteria and urges the scientific community to report the regrowth characteristics as well. This would increase the confidence in data interpretation that can provide a better understanding of chlorine tolerance in bacteria and aid in formulating strategies for effective chlorination.
Similar articles
-
Effects of wastewater disinfection on waterborne bacteria and viruses.Water Environ Res. 2007 Jan;79(1):81-92. doi: 10.2175/106143006x102024. Water Environ Res. 2007. PMID: 17290975
-
Inactivation, reactivation and regrowth of indigenous bacteria in reclaimed water after chlorine disinfection of a municipal wastewater treatment plant.J Environ Sci (China). 2013 Jul 1;25(7):1319-25. doi: 10.1016/s1001-0742(12)60176-4. J Environ Sci (China). 2013. PMID: 24218842
-
Investigation of chlorine tolerance profile of dominant gram negative bacteria recovered from secondary treated wastewater in Jaipur, India.J Environ Manage. 2020 Feb 1;255:109827. doi: 10.1016/j.jenvman.2019.109827. Epub 2019 Nov 15. J Environ Manage. 2020. PMID: 31739205
-
Formation and control of disinfection byproducts and toxicity during reclaimed water chlorination: A review.J Environ Sci (China). 2017 Aug;58:51-63. doi: 10.1016/j.jes.2017.01.013. Epub 2017 Feb 10. J Environ Sci (China). 2017. PMID: 28774626 Review.
-
Recent advances in drinking water disinfection: successes and challenges.Rev Environ Contam Toxicol. 2013;222:111-70. doi: 10.1007/978-1-4614-4717-7_4. Rev Environ Contam Toxicol. 2013. PMID: 22990947 Review.
Cited by
-
Synergistic Effects of Polydopamine/Medical Stone Bio-Adsorbents for Enhanced Interfacial Adsorption and Dynamic Filtration of Bacteria.Polymers (Basel). 2024 Oct 29;16(21):3027. doi: 10.3390/polym16213027. Polymers (Basel). 2024. PMID: 39518237 Free PMC article.
-
Operando investigation of the synergistic effect of electric field treatment and copper for bacteria inactivation.Nat Commun. 2024 Feb 14;15(1):1345. doi: 10.1038/s41467-024-45587-3. Nat Commun. 2024. PMID: 38355666 Free PMC article.
-
Combining Microbial Cellulose with FeSO4 and FeCl2 by Ex Situ and In Situ Methods.Polymers (Basel). 2025 Jun 23;17(13):1743. doi: 10.3390/polym17131743. Polymers (Basel). 2025. PMID: 40647754 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources