. 2022 Aug;44(8):1157-1163.
doi: 10.1007/s00276-022-02996-7. Epub 2022 Jul 31.

High resolution 3D magnetic resonance imaging of Gruber's ligament: a pilot study

Affiliations

High resolution 3D magnetic resonance imaging of Gruber's ligament: a pilot study

Marinos Kontzialis et al. Surg Radiol Anat. 2022 Aug.

Erratum in

Abstract

Introduction: Gruber's ligament (GL), a surgical landmark, extends from the lateral upper clivus to the petrous apex (PA), forming the superior boundary of Dorello's canal (DC). It overlies the interdural segment of the abducens nerve (CN VI). High-resolution 3D skull base MRI (SB-MRI) demonstrates anatomic details visible to the surgeon, but not well seen on traditional cross-sectional imaging. The aim of this study was to demonstrate visualization of the GL and its relationship to CN VI utilizing contrast enhanced high-resolution SB-MRI.

Methods: Two neuroradiologists retrospectively reviewed in consensus the SB-MRIs of 27 skull base sides, among 14 patients. GL detection rate, confidence of detection, and GL length were recorded. When GL was successfully identified, the position of the interdural segment of CN VI within DC was recorded.

Results: GL was readily identified in 16 skull base sides (59%), identified with some difficulty in 2 skull base sides (7%), and failed to be identified in 9 skull base sides (33%). The mean GL length was 7.1 mm (4.5-9.3 mm). Among the 18 cases where GL was successfully identified, CN VI was readily identified in all cases (100%), coursing the lateral third of DC in 72% of sides, and middle third in the remaining 28% of sides.

Conclusion: GL can be identified in approximately two-thirds of cases utilizing 3D high resolution SB-MRI. CN VI passes most commonly along the lateral third of DC. This is the first report demonstrating visualization of GL and its relation to CN VI, on imaging.

Keywords: Abducens nerve; Dorello’s canal; Gruber’s ligament; High-resolution 3D MRI; Petrous apex; Skull base.

PubMed Disclaimer

Similar articles

References

    1. Ambekar S, Sonig A, Nanda A (2012) Dorello’s canal and Gruber’s ligament: historical perspective. J Neurol Surg B Skull Base 73:430–433 - DOI
    1. Barges-Coll J, Fernandez-Miranda JC, Prevedello DM, Gardner P, Morera V, Madhok R, Carrau RL, Snyderman CH, Rhoton AL, Jr., Kassam AB (2010) Avoiding injury to the abducens nerve during expanded endonasal endoscopic surgery: anatomic and clinical case studies. Neurosurgery 67:144–54; discussion 154.
    1. Blitz AM, Choudhri AF, Chonka ZD, Ilica AT, Macedo LL, Chhabra A, Gallia GL, Aygun N (2014) Anatomic considerations, nomenclature, and advanced cross-sectional imaging techniques for visualization of the cranial nerve segments by MR imaging. Neuroimaging Clin N Am 24:1–15 - DOI
    1. Blitz AM, Macedo LL, Chonka ZD, Ilica AT, Choudhri AF, Gallia GL, Aygun N (2014) High-resolution CISS MR imaging with and without contrast for evaluation of the upper cranial nerves: segmental anatomy and selected pathologic conditions of the cisternal through extraforaminal segments. Neuroimaging Clin N Am 24:17–34 - DOI
    1. Chi SL, Bhatti MT (2009) The diagnostic dilemma of neuro-imaging in acute isolated sixth nerve palsy. Curr Opin Ophthalmol 20:423–429 - DOI

LinkOut - more resources