ICP monitoring--current status and future directions
Abstract
Continuous monitoring of intracranial pressure (ICP) is now an accepted part of neurosurgical practice, used in the management of patients with severe head injury, coma-producing subarachnoid haemorrhage, hydrocephalus, intracranial infection and following hypoxic or ischaemic insults to the brain. The pressure is measured from the lateral ventricle or from the subarachnoid space, and each neurosurgical department should establish criteria for determining what level of increased ICP should be acted upon and how it should be managed. This review favours a three stage approach: a) determining that ICP is truly elevated and correcting any immediately remediable causes, such as airway obstruction, then b) first-line measures, which consist of hyperventilation, osmotherapy and controlled CSF drainage, then c) second-line measures, consisting of short-acting anaesthetic agents--thiopentone and gammahydroxybutyrate. Future refinements of ICP monitoring will include improved understanding and better methods of measuring intracranial pressure-volume relationships and more detailed analysis of intracranial pulse pressure and the pressure waveform, its changes with mean ICP and its relationship with the arterial pressure waveform.
Similar articles
-
Management of head injury. Treatment of abnormal intracranial pressure.Neurosurg Clin N Am. 1991 Apr;2(2):267-84. Neurosurg Clin N Am. 1991. PMID: 1821741 Review.
-
Short-term continuous intraparenchymal intracranial pressure monitoring in presumed idiopathic intracranial hypertension.J Neuroophthalmol. 2011 Sep;31(3):202-5. doi: 10.1097/WNO.0b013e3182183c8d. J Neuroophthalmol. 2011. PMID: 21483268
-
Aggressive use of ICP monitoring is safe and alters patient care.Am Surg. 1995 Jan;61(1):24-9. Am Surg. 1995. PMID: 7832377
-
Monitoring and management of raised intracranial pressure (ICP) in the intensive care unit with an analysis of one year of intracranial pressure monitoring.J Assoc Physicians India. 1995 Nov;43(11):783-90. J Assoc Physicians India. 1995. PMID: 8773041 Review. No abstract available.
-
Long-term intracranial pressure recording in the management of pseudotumor cerebri.J Neurosurg. 1978 Aug;49(2):256-63. doi: 10.3171/jns.1978.49.2.0256. J Neurosurg. 1978. PMID: 671078
Cited by
-
Bedside ultrasound as a simple non-invasive method of assessing intracranial pressure in a limited resource setting.Afr J Emerg Med. 2016 Sep;6(3):e1-e4. doi: 10.1016/j.afjem.2016.06.002. Epub 2016 Jul 22. Afr J Emerg Med. 2016. PMID: 30456086 Free PMC article.
-
Brain compliance: the old story with a new 'et cetera'.Intensive Care Med. 2012 Jun;38(6):925-7. doi: 10.1007/s00134-012-2572-6. Epub 2012 Apr 18. Intensive Care Med. 2012. PMID: 22527086 No abstract available.
-
Bedside measurement of the third ventricle's diameter during episodes of arising intracranial pressure after head trauma. Using transcranial real-time sonography for a non-invasive examination of intracranial compensation mechanisms.Acta Neurochir (Wien). 1995;137(1-2):19-23; discussion 23-4. doi: 10.1007/BF02188774. Acta Neurochir (Wien). 1995. PMID: 8748862