Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 May;415(13):2425-2434.
doi: 10.1007/s00216-022-04245-7. Epub 2022 Aug 1.

Modeling of the first dimensional peak with two modulated sub-peaks in comprehensive two-dimensional gas chromatography

Affiliations

Modeling of the first dimensional peak with two modulated sub-peaks in comprehensive two-dimensional gas chromatography

Hui Mao et al. Anal Bioanal Chem. 2023 May.

Abstract

According to previous published works, precise modeling of the first dimensional (1D) peak in comprehensive two-dimensional gas chromatography (GC × GC) requires at least 3 modulated sub-peaks (MSP). This requirement is sometimes difficult to meet, e.g., in case of undersampling modulation. In the present work, the feasibility of modeling of the 1D peak with only 2 MSP was demonstrated. The effects of modulation phase (ϕ), modulation period (PM), the peak width (1σ), and the peak shape of the original 1D peak on the accuracy of the proposed method were explored. When employing PM ranging from 6 s ~ 3 s to modulate original peaks with 1σ = 1.2 s ~ 0.6 s, the maximal error of the modeled 1tR is 1.08 s, which is far less than the error generated by employing the largest MSP to estimate the 1tR. The deviation of modeled 1tR increases with the increase of peak shape distortion, and this deviation is ≤ 0.67 s when tailing factor (Tf) in the range of 0.8 to 1.5. The application of the proposed method was demonstrated by assisting identification of a monoterpene in Myrrh sample. The proposed approach could improve the accuracy in calculation of 1tR or 1I and enhance the reliability of compound identification in GC × GC analysis with undersampling modulation.

Keywords: Comprehensive two-dimensional gas chromatography; First dimensional retention time; Peak modeling; Retention index.

PubMed Disclaimer

Similar articles

References

    1. Zhu J, Niu Y, Xiao Z. Characterization of the key aroma compounds in Laoshan green teas by application of odour activity value (OAV), gas chromatography-mass spectrometry-olfactometry (GC-MS-O) and comprehensive two-dimensional gas chromatography mass spectrometry (GC × GC-qMS). Food Chem. 2021;339:128136. https://doi.org/10.1016/j.foodchem.2020.128136 . - DOI - PubMed
    1. Stilo F, Bicchi C, Reichenbach SE, Cordero C. Comprehensive two-dimensional gas chromatography as a boosting technology in food-omic investigations. J Sep Sci. 2021;44(8):1592–611. https://doi.org/10.1002/jssc.202100017 . - DOI - PubMed
    1. Wang X, Meng Q, Song H. Characterization of odor-active compounds in high-salt liquid-state soy sauce after cooking. Food Chem. 2022;373:131460. https://doi.org/10.1016/j.foodchem.2021.131460 .
    1. Prodhan MAI, Shi B, Song M, He L, Yuan F, Yin X, et al. Integrating comprehensive two-dimensional gas chromatography mass spectrometry and parallel two-dimensional liquid chromatography mass spectrometry for untargeted metabolomics. Analyst. 2019;144(14):4331–41. https://doi.org/10.1039/c9an00560a . - DOI - PubMed - PMC
    1. Prodhan M, McClain C, Zhang X. Comprehensive Two-Dimensional Gas Chromatography Mass Spectrometry-Based Metabolomics. Adv Exp Med Biol. 2021;1280:57–67. https://doi.org/10.1007/978-3-030-51652-9_4 . - DOI - PubMed

LinkOut - more resources