Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Jun 1:19:46.
eCollection 2022.

Microleakage of five separated nickel-titanium rotary file systems in the apical portion of the root canal

Affiliations

Microleakage of five separated nickel-titanium rotary file systems in the apical portion of the root canal

Seyed Mohsen Hasheminia et al. Dent Res J (Isfahan). .

Abstract

Background: The aim of this study was to evaluate the rate of apical microleakage following the fracture of five types of nickel-titanium rotary file systems (ProTaper Universal, Mtwo, RaCe, Revo-s, HeroShaper) in the apical one-third of the canal.

Materials and methods: In this laboratory experiment, 49 mandibular premolars were collected and randomly divided into seven groups. Root canal treatment was performed by five different rotary file systems with different cross-sections. All files, except in the control groups, were scratched at the 3-mm end by a handpiece. After separation of the apical end of the file in the root canal, the apical seal was measured, using the fluid infiltration technique. Data were analyzed in SPSS, using one-way ANOVA and Tamhane's T2 tests at P < 0.05.

Results: The Hero Shaper and RaCe files showed the highest (3.14 μL/min) and the lowest (2.51 µL/min) rates of microleakage over time, respectively. There were significant differences between the Hero Shaper and RaCe files and between Hero Shaper and ProTaper files in terms of microleakage (Tamhane's T2 tests, P < 0.05).

Conclusion: The presence of a separated file and its cross-section type affects the apical microleakage.

Keywords: Nickel–titanium; root canal treatment; rotary; separation.

PubMed Disclaimer

Conflict of interest statement

The authors of this manuscript declare that they have no conflicts of interest, real or perceived, financial or nonfinancial in this article.

Figures

Figure 1
Figure 1
The rate of microleakage in the experimental groups (microliter/min)

Similar articles

References

    1. Mohammadi Z. Sealing ability of MTA cements as orthograde root filling materials. Pesqui Bras Odontopediatria ClÍn Integr. 2009;8:267–70.
    1. Zarei M, Barzanoni M, Esmaieli H. An in vitro evaluation of apical leakage after root canal preparation by RC prep. J Mashhad Dent Sch. 2006;30:217–24.
    1. Ingle JI, Bakland LK, Baumgartner JC. Sixth Ed. Hamilton: BC Decker Inc.; 2008. Ingle’s endodontics 6.
    1. Alapati SB, Brantley WA, Svec TA, Powers JM, Nusstein JM, Daehn GS. SEM observations of nickel-titanium rotary endodontic instruments that separated during clinical use. J Endod. 2005;31:40–3. - PubMed
    1. Schäfer E, Schulz-Bongert U, Tulus G. Comparison of hand stainless steel and nickel titanium rotary instrumentation: A clinical study. J Endod. 2004;30:432–5. - PubMed