Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Feb;37(1):7-17.
doi: 10.1007/s10877-022-00899-x. Epub 2022 Aug 2.

The impact of continuous wireless monitoring on adverse device effects in medical and surgical wards: a review of current evidence

Affiliations

The impact of continuous wireless monitoring on adverse device effects in medical and surgical wards: a review of current evidence

Nikolaj Aagaard et al. J Clin Monit Comput. 2023 Feb.

Abstract

Novel technologies allow continuous wireless monitoring systems (CWMS) to measure vital signs and these systems might be favorable compared to intermittent monitoring regarding improving outcomes. However, device safety needs to be validated because uncertain evidence challenges the clinical implementation of CWMS. This review investigates the frequency of device-related adverse events in patients monitored with CWMS in general hospital wards. Systematic literature searches were conducted in PubMed and Embase. We included trials of adult patients in general hospital wards monitored with CWMS. Our primary outcome was the frequency of unanticipated serious adverse device effects (USADEs). Secondary outcomes were adverse device effects (ADEs) and serious adverse device effects (SADE). Data were extracted from eligible studies and descriptive statistics were applied to analyze the data. Seven studies were eligible for inclusion with a total of 1485 patients monitored by CWMS. Of these patients, 54 patients experienced ADEs (3.6%, 95% CI 2.8-4.7%) and no USADEs or SADEs were reported (0%, 95% CI 0-0.31%). The studies of the SensiumVitals® patch, the iThermonitor, and the ViSi Mobile® device reported 28 (9%), 25 (5%), and 1 (3%) ADEs, respectively. No ADEs were reported using the HealthPatch, WARD 24/7 system, or Coviden Alarm Management. Current evidence suggests that CWMS are safe to use but systematic reporting of all adverse device effects is warranted.

Keywords: Adverse device effects; Continuous wireless monitoring systems; Device safety; Medical wards; Surgical wards; Unanticipated adverse device effects.

PubMed Disclaimer

Similar articles

Cited by

References

    1. McQuillan P, Pilkington S, Allan A, Taylor B, Short A, Morgan G, et al. Confidential inquiry into quality of care before admission to intensive care. BMJ. 1998. https://doi.org/10.1136/bmj.316.7148.1853 . - DOI
    1. Watkinson PJ, Barber VS, Price JD, Hann A, Tarassenko L, Young JD. A randomised controlled trial of the effect of continuous electronic physiological monitoring on the adverse event rate in high risk medical and surgical patients. Anaesthesia. 2006. https://doi.org/10.1111/j.1365-2044.2006.04818.x . - DOI
    1. McGloin H, Adam SK, Singer M. Unexpected deaths and referrals to intensive care of patients on general wards. Are some cases potentially avoidable? J R Coll Physicians Lond. 1999;33(3):255–9.
    1. Tarassenko L, Hann A, Young D. Integrated monitoring and analysis for early warning of patient deterioration. Br J Anaesth. 2006. https://doi.org/10.1093/bja/ael113 . - DOI
    1. Javanbakht M, Mashayekhi A, Trevor M, Rezaei Hemami M, Downey CL, Branagan-Harris M, et al. Cost utility analysis of continuous and intermittent versus intermittent vital signs monitoring in patients admitted to surgical wards. J Med Econ. 2020. https://doi.org/10.1080/13696998.2020.1747474 . - DOI

Publication types

LinkOut - more resources