Effect of simulated brushing and disinfection on the surface roughness and color stability of CAD-CAM denture base materials
- PMID: 35917636
- DOI: 10.1016/j.jmbbm.2022.105390
Effect of simulated brushing and disinfection on the surface roughness and color stability of CAD-CAM denture base materials
Abstract
Purpose: To evaluate the effect of simulated brushing and chemical disinfection on the surface roughness and color stability of CAD-CAM denture base materials and to compare with those of a heat-cured denture base material.
Material and methods: Disk-shaped specimens (Ø 10mm × 2 mm) were prepared from 3 CAD-CAM denture base resins (AvaDent, Ava; Merz M-PM, Merz; Polident d.o.o, Poli) and a heat-cured polymethylmethacrylate resin (Promolux, Conv) (n = 30). After polishing, baseline surface roughness (Ra) and color coordinates were measured. The measurements were repeated after 20000 cycles of simulated brushing, and the specimens were divided into 3 groups according to disinfection protocol (distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet) (n = 10). After 9 cleaning cycles over a period of 20 days, Ra and color coordinates were remeasured. Color differences (ΔE00) were calculated by using CIEDE2000 formula. One-way analysis of variance (ANOVA) and pairwise t-tests were used to analyze Ra and ΔE00 data, while repeated measures ANOVA test was used to compare baseline, after brush, and after disinfection Ra values (α = 0.05).
Results: Brushing did not affect the Ra values of tested materials (P ≥ .08). Both before and after brushing, Merz and Conv had higher Ra values than Poli and Ava (P < .001). Among disinfectants, effervescent tablet led to the lowest Ra for Merz (P = .003) and the highest Ra for Poli (P ≤ .039). Only NaOCl resulted in significant differences among the Ra of materials (P < .001), as Merz and Conv had higher Ra values than Poli (P ≤ .002). Repeated measures ANOVA revealed that effervescent tablet disinfection of Merz led to lower Ra values than those of baseline and after brushing (P ≤ .042). After brushing, Ava and Conv had higher ΔE00 values compared with Merz and Poli (P ≤ .015). When compared with other disinfection protocols, effervescent tablet led to higher ΔE00 values for Merz and Poli (P < .001). Significant differences were observed among materials when NaOCl was used; Conv had higher ΔE00 values than Ava and Merz (P = .004).
Conclusions: Brushing did not increase the surface roughness of materials. Disinfection protocol's effect on the surface roughness varied. The effect of brushing on the color of materials varied; color of Ava and Conv was affected from brushing more than the other materials. Color stability of materials varied depending on the disinfection protocol. Effervescent tablet caused higher color change with Merz and Poli compared with other disinfectants. NaOCl led to small color change for Poli, Ava, and Merz materials.
Keywords: CAD-CAM; Color stability; Denture base; Disinfection; Simulated brushing; Surface roughness.
Copyright © 2022 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Conflict of interest statement
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Similar articles
-
Surface roughness and stainability of CAD-CAM denture base materials after simulated brushing and coffee thermocycling.J Prosthet Dent. 2024 Jul;132(1):260-266. doi: 10.1016/j.prosdent.2022.06.006. Epub 2022 Aug 20. J Prosthet Dent. 2024. PMID: 35995602
-
Effect of polishing and denture cleansers on the surface roughness of new-generation denture base materials and their color change after cleansing.J Prosthodont. 2024 Oct;33(8):783-790. doi: 10.1111/jopr.13755. Epub 2023 Sep 8. J Prosthodont. 2024. PMID: 37624691
-
Effect of different disinfection protocols on the surface properties of CAD-CAM denture base materials.J Prosthet Dent. 2023 Nov;130(5):787-795. doi: 10.1016/j.prosdent.2021.12.007. Epub 2022 Feb 9. J Prosthet Dent. 2023. PMID: 35148889
-
Effect of coffee thermal cycling on the surface properties and stainability of additively manufactured denture base resins in different layer thicknesses.J Prosthodont. 2025 Feb;34(2):157-166. doi: 10.1111/jopr.13803. Epub 2023 Dec 6. J Prosthodont. 2025. PMID: 37968565 Free PMC article.
-
Scientific evidence on the efficacy of effervescent tablets for cleaning removable prostheses. A systematic review and meta-analysis.J Prosthet Dent. 2024 Jun;131(6):1071-1083. doi: 10.1016/j.prosdent.2023.01.031. Epub 2023 Mar 2. J Prosthet Dent. 2024. PMID: 36870893
Cited by
-
Nanoparticle-Modified 3D-Printed Denture Base Resins: Influence of Denture Cleansers on the Color Stability and Surface Roughness In Vitro.Nanomaterials (Basel). 2024 May 20;14(10):891. doi: 10.3390/nano14100891. Nanomaterials (Basel). 2024. PMID: 38786847 Free PMC article.
-
Comparative Evaluation of Disinfection Protocols for Dental Impressions in Prosthodontics.Cureus. 2024 Jul 27;16(7):e65535. doi: 10.7759/cureus.65535. eCollection 2024 Jul. Cureus. 2024. PMID: 39188490 Free PMC article.
-
Surface Roughness and Color Stability of 3D-Printed Denture Base Materials after Simulated Brushing and Thermocycling.Materials (Basel). 2022 Sep 16;15(18):6441. doi: 10.3390/ma15186441. Materials (Basel). 2022. PMID: 36143757 Free PMC article.
-
Influence of thermal-cycling or staining medium on the surface properties and color stability of conventional, milled, and 3D-printed base materials.Sci Rep. 2024 Nov 22;14(1):28928. doi: 10.1038/s41598-024-80380-8. Sci Rep. 2024. PMID: 39572646 Free PMC article.