Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Oct;45(10):1462-1469.
doi: 10.1007/s00270-022-03230-y. Epub 2022 Aug 4.

Minimally Invasive Segmental Artery Coil Embolization (MISACE) Prior to Endovascular Thoracoabdominal Aortic Aneurysm Repair

Affiliations

Minimally Invasive Segmental Artery Coil Embolization (MISACE) Prior to Endovascular Thoracoabdominal Aortic Aneurysm Repair

Jamil A K Addas et al. Cardiovasc Intervent Radiol. 2022 Oct.

Abstract

Purpose: Minimally Invasive Segmental Artery Coil Embolization (MISACE) is a novel approach to reduce paraplegia risk in Thoracoabdominal aortic aneurysm (TAAA) repair with limited data. We report our experience with MISACE as a method of spinal cord pre-conditioning to prevent spinal cord ischemia following endovascular repair of TAAA.

Material and methods: A retrospective analysis of 17 patients who had an attempted MISACE prior to endovascular TAAA repair with mean follow-up of 350 days (2017-2020). Baseline patient and aneurysm characteristics along with procedural technique and outcomes were analyzed.

Results: Mean age of 69 years and 76.5% were males. TAAA Crawford classification were II, n = 6 (35.3%), III, n = 4 (23.5%) and IV, n = 5 (29.4%). The mean aortic diameter was 70.6 ± 10.9 mm. Staged repair was performed on 9 patients. Technically successful embolization occurred in 14 patients (82.4%) and was unsuccessful in 3 patients. The median number of embolized arteries was 3 and 71% of the target arteries were between T9 and T12. Mean fluoroscopy time was 51.5 ± 22.5 min and mean contrast volume used was 132.8 ± 56.1 mL. Average number of catheters used was 4.6 and 3.5 wires. No complications related to the procedure. Mean interval between embolization to endovascular TAAA repair was 51.2 days (5-110 days). All patients received spinal drainage at the time of repair. Postoperatively, 2/14 of patients developed paraparesis in the MISACE successful group and 1/3 patients developed paraplegia in the unsuccessful group.

Conclusions: MISACE is a promising strategy to prevent SCI. This data demonstrates the technique is feasible and safe but anatomic challenges remain.

Keywords: MISACE; Segmental arteries; Spinal cord ischemia; TAAA.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Jacobs MJ, Schurink GW, Mees BM. Spinal cord ischaemia after complex aortic procedures. Eur J Vasc Endovasc Surg. 2016;52(3):279–80. - DOI
    1. Branzan D, Etz CD, Moche M, Von Aspern K, Staab H, Fuchs J. Ischaemic preconditioning of the spinal cord to prevent spinal cord ischaemia during endovascular repair of thoracoabdominal aortic aneurysm: first clinical experience. EuroIntervention. 2018;14(7):828–35. - DOI
    1. Greenberg RK, Lu Q, Roselli EE, Svensson LG, Moon MC, Hernandez AV, Dowdall J, Cury M, Francis C, Pfaff K, Clair DG, Ouriel K, Lytle BW. Contemporary analysis of descending thoracic and thoracoabdominal aneurysm repair: a comparison of endovascular and open techniques. Circulation. 2008;118(8):808–17. https://doi.org/10.1161/CIRCULATIONAHA.108.769695 (Epub 2008 Aug 4 PMID: 18678769). - DOI - PubMed
    1. Rocha RV, Lindsay TF, Friedrich JO, Shan S, Sinha S, Yanagawa B, Al-Omran M, Forbes TL, Ouzounian M. Systematic review of contemporary outcomes of endovascular and open thoracoabdominal aortic aneurysm repair. J Vasc Surg. 2020;71(4):1396–412. - DOI
    1. Aucoin VJ, Eagleton MJ, Farber MA, Oderich GS, Schanzer A, Timaran CH, Schneider DB, Sweet MP, Beck AW. Spinal cord protection practices used during endovascular repair of complex aortic aneurysms by the US Aortic research consortium. J Vasc Surg. 2021;73(1):323–30. - DOI

LinkOut - more resources