SEAPAL quality control analysis of rheumatoid factor measurement in 29 diagnostic laboratories
- PMID: 3592802
- PMCID: PMC1002152
- DOI: 10.1136/ard.46.5.417
SEAPAL quality control analysis of rheumatoid factor measurement in 29 diagnostic laboratories
Abstract
A programme for rheumatoid factor (RF) measurement was sponsored by the South East Asian Pacific League against Rheumatism (SEAPAL) and the Clinical Immunology Group (CIG) of the Australian Society for Immunology. Measurements in 29 laboratories in 12 countries showed: a large variety of methods were being used to measure RF, most using semiquantitative agglutination techniques; some laboratories have invalid techniques; the quoted upper normal limit varied considerably between assays, and false positives were identified in three laboratories; a wide range of intralaboratory precision within and between assays; and a reduction in discordance between laboratories by the inclusion of local standards. Before international standardisation of RF measurement can be achieved attention to many of these problems is required. In particular we recommend the wider use of reference standards and the regular participation in quality control programmes in order to monitor performance.
Similar articles
-
Common tests for rheumatoid factors: poorly standardized but ubiquitous.Arthritis Rheum. 1988 Mar;31(3):432-5. doi: 10.1002/art.1780310317. Arthritis Rheum. 1988. PMID: 3358805
-
[Recent problems in laboratory tests for rheumatoid factor].Rinsho Byori. 1993 Aug;41(8):835-40. Rinsho Byori. 1993. PMID: 8371498 Japanese.
-
Standardisation of serological tests for rheumatoid factor measurement.Ann Rheum Dis. 1987 Sep;46(9):674-80. doi: 10.1136/ard.46.9.674. Ann Rheum Dis. 1987. PMID: 3499874 Free PMC article.
-
Veterinary diagnostic laboratories in developing countries: the challenge of credibility.Rev Sci Tech. 1998 Aug;17(2):454-8. doi: 10.20506/rst.17.2.1111. Rev Sci Tech. 1998. PMID: 9713890 Review.
-
International reference standards in coagulation.Biologicals. 2010 Jul;38(4):423-9. doi: 10.1016/j.biologicals.2010.02.009. Epub 2010 Mar 24. Biologicals. 2010. PMID: 20338786 Review.
Cited by
-
Rate nephelometric determination of rheumatoid factor: comparison between Kallestad QM-300 and Beckman ICS-II (RF) methods.J Clin Pathol. 1990 Mar;43(3):243-5. doi: 10.1136/jcp.43.3.243. J Clin Pathol. 1990. PMID: 2332520 Free PMC article.
-
Rheumatoid factor measurement--continuing problems 70 years after discovery.Clin Rheumatol. 2011 Sep;30(9):1215-20. doi: 10.1007/s10067-011-1716-3. Epub 2011 Apr 1. Clin Rheumatol. 2011. PMID: 21455659
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources