Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2022 Jun:137:212846.
doi: 10.1016/j.bioadv.2022.212846. Epub 2022 May 8.

Pharmaceutical-eluting hybrid degradable hydrogel/microparticle loaded sacs for finger joint interpositional arthroplasty

Affiliations

Pharmaceutical-eluting hybrid degradable hydrogel/microparticle loaded sacs for finger joint interpositional arthroplasty

Yung-Heng Hsu et al. Biomater Adv. 2022 Jun.

Abstract

Despite recent advances in medical technology, treatment of chronic osteomyelitis in the small joint of the hand remains challenging. Here, we exploited hybrid biodegradable hydrogel/microparticle/polycaprolactone (PCL) sacs for finger joint interpositional arthroplasty via electrospraying and rotational molding techniques. Degradable Pluronic F127, poly(lactic-co-glycolic acid) (PLGA), and PCL were starting materials for the hydrogels, microparticles, and sac, respectively. Vancomycin, ceftazidime, and lidocaine were the embedded pharmaceuticals. The in vitro and in vivo drug release behaviors of hybrid drug-eluting sacs were assessed. The empirical outcomes show that the size distribution of the electrosprayed vancomycin/ceftazidime/lidocaine PLGA microparticles was 8.25 ± 3.35 μm. Biodegradable PCL sacs offered sustainable and effective release of vancomycin, ceftazidime, and lidocaine, respectively, after 30, 16, and 11 days in vitro. The sacs also discharged high levels of anti-microbial agents for 56 days and analgesics for 14 days in a rabbit knee joint model. The blood urea nitrogen (creatinine) levels remained normal at various time points: 16.5 ± 2.5 mg/dL (0.85 ± 0.24 mg/dL), 20.0 ± 1.4 mg/dL (1.0 ± 0.16 mg/dL), 19.3 ± 2.4 mg/dL (1.13 ± 0.15 mg/dL), and 20.0 ± 2.16 mg/dL (1.0 ± 0.16 mg/dL) at days 7, 14, 21, and 35, respectively. The empirical outcomes of this study suggested that the hybrid biodegradable drug-eluting sacs with extended liberation of pharmaceuticals may find applications in the small joints for post-operative pain relief and infection control.

Keywords: Degradable drug-eluting sac; Electrospraying; Infection control; Pain relief; Release behaviors; Rotational molding.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources