Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Mar;14(2):429-437.
doi: 10.1177/21925682221109563. Epub 2022 Aug 5.

Prospective Multicenter Trial of Cervical Arthroplasty with the ROTAIO® Cervical Disc Prosthesis

Affiliations

Prospective Multicenter Trial of Cervical Arthroplasty with the ROTAIO® Cervical Disc Prosthesis

Steffen Fleck et al. Global Spine J. 2024 Mar.

Abstract

Study design: Clinical observational study.

Objective: The ROTAIO® cervical disc prosthesis is a novel unconstrained implant with a variable center of rotation aiming at physiological motion. The objective of this multicenter prospective trial was to evaluate clinical outcome and complications within 2 years.

Material and methods: 120 patients (72 females and 48 males with median age of 43.0 years [23-60 yrs] underwent ACDA (ROTAIO®, SIGNUS Medical, Alzenau, Germany) and were prospectively followed for 24 months. Preoperative complaints were mainly associated with radiculopathy (n = 104) or myelopathy (n=16). There were 108 monosegmental and 12 bisegmental procedures including 6 hybrid constructs. Clinical outcome was evaluated at 3, 12 and 24 months in 100%, 96% and 77% of the cohort by VAS, NDI, WL-26, Patient`s Satisfaction Index (PSI), SF-36, Nurick Score, mJOA, Composite Success Rate, complications, patient`s overall satisfaction and analgesics use.

Results: Highly significant clinical improvements were observed according to NDI and VAS (P < .0001 (arm); P < .001 (neck); P = .002 (head)) at all time points. Analgetic use could be reduced in 87.1 to 95.2%. Doctor`s visits have been reduced in 93.8% after 24 months. Patient`s overall satisfaction was high with 78.4 to 83.5% of patients. The composite success rate was 77.5% after 12 months and 76.9% after 24 months. There were no major complications in this series. Slight subsidence of the prosthesis was observed in 2 patients and 3 patients demonstrated fusion after 24 months. 2 patients developed symptomatic foraminal stenosis, so that implant removal and fusion was performed resulting in a revision rate of 1.7% in 2 years.

Conclusion: The ROTAIO® cervical disc prosthesis is a safe and efficient treatment option for symptomatic degenerative disc disease demonstrating highly significant clinical improvement and high patient`s overall satisfaction with very low revision rates at 2 years.

Keywords: adjacent segment disease; cervical arthroplasty; cervical disc prosthesis; complications; outcome.

PubMed Disclaimer

Conflict of interest statement

Declaration of conflicting interestsThe author(s) declared the following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: CT, CU, RG and JUM are consultants to SIGNUS Medizintechnik GmbH.

Figures

Figure 1.
Figure 1.
The ROTAIO® cervical disc prosthesis allows uncoupled anterior translation upon flexion and posterior translation upon extension mimicking natural disc motion.

References

    1. Smith GW, Robinson RA. The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. J Bone Joint Surg Am. 1958;40-A(3):607-624. - PubMed
    1. Fraser JF, Hartl R. Anterior approaches to fusion of the cervical spine: a metaanalysis of fusion rates. J Neurosurg Spine. 2007;6(4):298-303. doi: 10.3171/spi.2007.6.4.2 - DOI - PubMed
    1. Shriver MF, Lewis DJ, Kshettry VR, Rosenbaum BP, Benzel EC, Mroz TE. Pseudoarthrosis rates in anterior cervical discectomy and fusion: a meta-analysis. Spine J. 2015;15(9):2016-2027. doi: 10.1016/j.spinee.2015.05.010 - DOI - PubMed
    1. Anderson PA, Sasso RC, Hipp J, Norvell D, Raich A, Hashimoto R. Kinematics of the cervical adjacent segments following disc arthroplasty and anterior discectomy and fusion: A systematic review and meta-analysis. Spine. 2012;37:S85-95. doi: 10.1097/BRS.0b013e31826d6628 - DOI - PubMed
    1. Reitman CA, Hipp JA, Nguyen L, Esses SI. Changes in segmental intervertebral motion adjacent to cervical arthrodesis: A prospective study. Spine. 2004;29(11):E221-E226. - PubMed