Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2022 Oct 14;28(20):4425-4434.
doi: 10.1158/1078-0432.CCR-22-0094.

89Zr-panitumumab Combined With 18F-FDG PET Improves Detection and Staging of Head and Neck Squamous Cell Carcinoma

Affiliations
Clinical Trial

89Zr-panitumumab Combined With 18F-FDG PET Improves Detection and Staging of Head and Neck Squamous Cell Carcinoma

Yu-Jin Lee et al. Clin Cancer Res. .

Abstract

Purpose: Determine the safety and specificity of a tumor-targeted radiotracer (89Zr-pan) in combination with 18F-FDG PET/CT to improve diagnostic accuracy in head and neck squamous cell carcinoma (HNSCC).

Experimental design: Adult patients with biopsy-proven HNSCC scheduled for standard-of-care surgery were enrolled in a clinical trial and underwent systemic administration of 89Zirconium-panitumumab and panitumumab-IRDye800 followed by preoperative 89Zr-pan PET/CT and intraoperative fluorescence imaging. The sensitivity, specificity, and AUC were evaluated.

Results: A total of fourteen patients were enrolled and completed the study. Four patients (28.5%) had areas of high 18F-FDG uptake outside the head and neck region with maximum standardized uptake values (SUVmax) greater than 2.0 that were not detected on 89Zr-pan PET/CT. These four patients with incidental findings underwent further workup and had no evidence of cancer on biopsy or clinical follow-up. Forty-eight lesions (primary tumor, LNs, incidental findings) with SUVmax ranging 2.0-23.6 were visualized on 18F-FDG PET/CT; 34 lesions on 89Zr-pan PET/CT with SUVmax ranging 0.9-10.5. The combined ability of 18F-FDG PET/CT and 89Zr-pan PET/CT to detect HNSCC in the whole body was improved with higher specificity of 96.3% [confidence interval (CI), 89.2%-100%] compared to 18F-FDG PET/CT alone with specificity of 74.1% (CI, 74.1%-90.6%). One possibly related grade 1 adverse event of prolonged QTc (460 ms) was reported but resolved in follow-up.

Conclusions: 89Zr-pan PET/CT imaging is safe and may be valuable in discriminating incidental findings identified on 18F-FDG PET/CT from true positive lesions and in localizing metastatic LNs.

PubMed Disclaimer

Comment in

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources